Show simple item record

dc.contributor.authorDogan, Orhan Murat
dc.contributor.authorKeskin, Selda
dc.contributor.authorDogan, Arife
dc.contributor.authorAtaman, Hande
dc.contributor.authorUsanmaz, Ali
dc.date.accessioned2019-07-27T12:10:23Z
dc.date.accessioned2019-07-28T10:16:40Z
dc.date.available2019-07-27T12:10:23Z
dc.date.available2019-07-28T10:16:40Z
dc.date.issued2007
dc.identifier.issn0287-4547
dc.identifier.urihttps://dx.doi.org/10.4012/dmj.26.329
dc.identifier.urihttps://hdl.handle.net/20.500.12418/10615
dc.descriptionWOS: 000248252000005en_US
dc.descriptionPubMed ID: 17694740en_US
dc.description.abstractWith a view to understanding the structure-property relation of a silicone-based soft lining denture material after polymerization, its chemical composition and viscoelastic properties were investigated. Chemical compositions of the cured and uncured polymers of a commercial silicone permanent soft liner were determined by infrared spectroscopic analysis, nuclear magnetic resonance (NMR), and X-ray photoelectron spectroscopy. Dynamic mechanical analysis (DMA) method was used to investigate the viscoelastic behavior of the cured polymer of liner. Spectroscopic analysis showed that the main component of soft liner was vinyl-terminated poly (dim ethylsiloxane), and the adhesive was 3-methacryloxypropyltrimethoxy silane. NMR results revealed that other components included benzoyl peroxide as initiator for polymerization and also silicilic acid. Surface analysis by XPS provided interesting insights about the nature of adhesive bonding, as well as diffusion of silicilic acid through the matrix of the processed material and leaching-out. DMA results showed a two-phase character, and that the cured polymer was highly elastic.en_US
dc.language.isoengen_US
dc.publisherJAPANESE SOC DENTAL MATERIALS DEVICESen_US
dc.relation.isversionof10.4012/dmj.26.329en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectlineren_US
dc.subjectchemical compositionen_US
dc.subjectviscoelasticityen_US
dc.titleStructure-property relation of a soft liner material used in denture applicationsen_US
dc.typearticleen_US
dc.relation.journalDENTAL MATERIALS JOURNALen_US
dc.contributor.departmentCumhuriyet Univ, Dept Prosthodont, Fac Dent, Sivas, Turkey -- Middle E Tech Univ, Dept Chem, Ankara, Turkey -- Gazi Univ, Fac Dent, Dept Prosthodont, Ankara, Turkeyen_US
dc.identifier.volume26en_US
dc.identifier.issue3en_US
dc.identifier.endpage334en_US
dc.identifier.startpage329en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record