Show simple item record

dc.contributor.authorKaptan A
dc.contributor.authorOZNURHAN, F.
dc.contributor.authorCandan, M
dc.date.accessioned2024-02-29T08:55:02Z
dc.date.available2024-02-29T08:55:02Z
dc.date.issued27.01.2023tr
dc.identifier.citationKaptan A, Oznurhan F, Candan M. In Vitro Comparison of Surface Roughness, Flexural, and Microtensile Strength of Various Glass-Ionomer-Based Materials and a New Alkasite Restorative Material. Polymers (Basel). 2023 Jan 27;15(3):650. doi: 10.3390/polym15030650. PMID: 36771950; PMCID: PMC9920171.tr
dc.identifier.urihttps://www.mdpi.com/2073-4360/15/3/650
dc.identifier.urihttps://hdl.handle.net/20.500.12418/14459
dc.description.abstractAbstract: This study aims to evaluate the physical properties of Cention N and various glass-ionomerbased materials in vitro. The groups were obtained as follows: Group 1 (LC-Cent): light-cured Cention N; Group 2 (SC-Cent): self-cured Cention N; Group 3 (COMP): composite (3M Universal Restorative 200); Group 4 (DYRA): compomer (Dyract XP); Group 5 (LINER): Glass Liner; Group 6 (FUJI): FujiII LC Capsule; and Group 7 (NOVA): Nova Glass LC. For the microtensile bond strength ( TBS) test, 21 extracted human molar teeth were used. The enamel of the teeth was removed, and flat dentin surfaces were obtained. Materials were applied up to 3 mm, and sticks were obtained from the teeth. Additionally, specimens were prepared, and their flexural strength and surface roughness (Ra) were evaluated. Herein, data were recorded using SPSS 22.0, and the flexural strength, TBS, and Ra were statistically analyzed. According to the surface roughness tests, the highest Ra values were observed in Group 6 (FUJI) (0.33 0.1), whereas the lowest Ra values were observed in Group 2 (SCCent) (0.17 0.04) (p < 0.05). The flexural strengths of the materials were compared, and the highest value was obtained in Group 2 (SC-Cent) (86.32 15.37), whereas the lowest value was obtained in Group 5 (LINER) (41.75 10.05) (p < 0.05). When the TBS of materials to teeth was evaluated, the highest TBS was observed in Group 3 (COMP) (16.50 7.73) and Group 4 (DYRA) (16.36 4.64), whereas the lowest TBS was found in Group 7 (NOVA) (9.88 1.87) (p < 0.05). According to the TBS results of materials-to-materials bonding, both Group 2 (SC-Cent) and Group 1 (LC-Cent) made the best bonding with Group 3 (COMP) (p < 0.05). It can be concluded that self-cured Cention N had the highest flexural strength and lowest surface roughness of the seven materials tested. Although the bond strength was statistically lower than conventional composites and compomers, it was similar to resin-modified glass ionomer cements. Additionally, the best material-to-material bonding was found between self-cured Cention N and conventional compositestr
dc.language.isoengtr
dc.publisherMDPI AGtr
dc.relation.isversionof10.3390/polym15030650tr
dc.rightsinfo:eu-repo/semantics/openAccesstr
dc.subjectCention N; alkasite restorative; self-cured restorative; resin-modified glass ionomer cement; microtensile bond strengthtr
dc.titleIn Vitro Comparison of Surface Roughness, Flexural, and Microtensile Strength of Various Glass-Ionomer-Based Materials and a New Alkasite Restorative Materialtr
dc.typeanimationtr
dc.relation.journalPolymers (Basel)tr
dc.contributor.departmentDiş Hekimliği Fakültesitr
dc.contributor.authorID0000-0002-7797-0932tr
dc.identifier.volume15tr
dc.identifier.issue650tr
dc.identifier.endpage11tr
dc.identifier.startpage1tr
dc.relation.publicationcategoryUluslararası Hakemli Dergide Makale - Kurum Öğretim Elemanıtr


Files in this item

This item appears in the following Collection(s)

Show simple item record