dc.description.abstractAmaç: Bu çalışmada duktus arteriyozus açıklığının (DAA) transkateter yöntemle tedavisinde Amplatzer Duct Occluder II’nin (ADO II) etkinliği, güvenirliği ve kısa-orta dönem takip sonuçları değerlendirildi. Çalışma planı: Çalışmada DAA tanısıyla ADO II ile perkütan kapatma uygulanan 16 hasta (10 kız, 6 erkek; ortanca yaş 6; dağılım 5 ay-12 yıl) değerlendirildi. Tüm olgularda DAA çapı 6 mm’nin altında idi. Krichenko sınıflandırmasına göre, 10 hastada tip A, beş hastada tip E, bir hastada da cerrahi sonrası rezidüel DAA vardı. İşlem sonrasında hastalar aortografi ve ekokardiyografi ile değerlendirildi. Ortalama takip süresi 13.9 ay (dağılım 2-23 ay) idi. Bulgular: Kapatma işlemi tüm hastalarda arteryel yaklaşımla başarıyla gerçekleştirildi. Kanalın en dar olduğu yerin ortancası 3 mm (dağılım 2-5 mm), cihaz bel çapının ortancası 4 mm (dağılım 3-6 mm), cihaz bel uzunluğu 4 veya 6 mm idi. Floroskopi süresi ortalama 10.6 dk (dağılım 4-39 dk), işlem süresi ortalama 30 dk (dağılım 18-80 dk) bulundu. İşlemden hemen sonra yapılan aortografide sadece cihaz içinden geçiş izlendi. İşlem sonrası ve takipler sırasında yapılan ekokardiyografik incelemelerde ise hiçbir hastada kaçak, aort ve sol pulmoner arter akımlarında anlamlı hızlanma izlenmedi. Hiçbir hastada komplikasyonla görülmedi. Sonuç: Tüm olgularda ADO II cihazının 6 mm’den küçük DAA’ların kapatılmasında etkin ve güvenilir olduğu görüldü.en_US
dc.description.abstractObjectives: We evaluated the effectiveness and reliability of percutaneous closure of persistent arterial duct (PAD) with the Amplatzer Duct Occluder II (ADO II), together with short- and mid-term results. Study design: The study included 16 patients (10 girls, 6 boys; median age 6 years; range 5 months to 12 years) who underwent percutaneous PAD closure with the ADO II device. The ductus diameter was less than 6 mm in all the cases. According to the Krichenko classification, 10 patients had type A, five patients had type E, and one patient had residual PAD. The patients were assessed by aortography and echocardiography. The mean follow-up was 13.9 months (range 2 to 23 months). Results: Closure of PAD was successfully performed via the arterial approach in all the patients. The median ductus waist diameter was 3 mm (range 2 to 5 mm), the median device waist diameter was 4 mm (range 3 to 6 mm), and the waist length was 4 or 6 mm. The mean fluoroscopy time and the mean procedure time were 10.6 min (range 4 to 39 min) and 30 min (range 18 to 80 min), respectively. Immediate aortography following the procedure showed shunt only through the device lumen. No residual shunt or increases in aortic and left pulmonary flow velocities were observed in echocardiographic examinations. No complications occurred during the procedure and follow-up. Conclusion: In all the cases, the ADO II device was found effective and reliable for closure of PADs of less than 6 mm.en_US
dc.language.isoturen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectKalp ve Kalp Damar Sistemien_US
dc.titleDuktus arteriyozus açıklığının Amplatzer Duct Occluder II ile perkütan kapatılmasında işlem başarısı ve kısa-orta dönem takip sonuçlarıen_US
dc.title.alternativeProcedural success and short- and mid-term results of percutaneous closure of persistent arterial duct with the Amplatzer Duct Occluder IIen_US
dc.typearticleen_US
dc.relation.journalTürk Kardiyoloji Derneği Arşivien_US
dc.contributor.departmentSivas Cumhuriyet Üniversitesien_US
dc.identifier.volume39en_US
dc.identifier.issue3en_US
dc.identifier.endpage223en_US
dc.identifier.startpage219en_US