Show simple item record

dc.contributor.authorGürkan R.
dc.contributor.authorAltunay N.
dc.contributor.authorYıldırım E.
dc.date.accessioned2019-07-27T12:10:23Z
dc.date.accessioned2019-07-28T09:31:28Z
dc.date.available2019-07-27T12:10:23Z
dc.date.available2019-07-28T09:31:28Z
dc.date.issued2016
dc.identifier.issn1936-9751
dc.identifier.urihttps://dx.doi.org/10.1007/s12161-016-0505-7
dc.identifier.urihttps://hdl.handle.net/20.500.12418/5256
dc.descriptionSpringer New York LLCen_US
dc.description.abstractIn this article, ultrasonic-assisted cloud point extraction (UA-CPE) was used to the preconcentration of trace Ag(I) and Cd(II) in dried nut and vegetable samples. After ion association of Ag(I) and Cd(II) ions with 3,7-diamino-2,8-dimethyl-5-phenyl-phenaziniumchlorid (Safranin T) in the presence of excess potassium iodide (KI) at pH 6.0, the ternary complexes formed were quantitatively extracted into a micellar phase of poly(ethyleneglycol-mono-p-nonylphenylether) (PONPE 7.5) and then determined by flame atomic absorption spectrometry (FAAS). The matrix effects of possible some interfering ions on the method recovery and tolerance limits were also investigated. Under the optimized reagent conditions, the method was linearly dependent on the analyte concentrations in the range of 0.08–90 and 3–250 ?g L?1 with limits of detection of 0.02 and 0.9 ?g L?1 for Ag(I) and Cd(II), respectively. The reproducibility as the percent relative standard deviations (RSDs %) (0.5, 5.0, and 25 ?g L?1 for Ag(I) and 15, 30, and 100 ?g L?1 for Cd(II), n = 6) was lower than 3.6 % for both analytes. The accuracy of the method was controlled by analysis of two certified samples (SRM 1573a Tomato leaves and SRM 1643e Trace elements in waters) as well as recovery studies from spiked samples. It has been observed that the results obtained are in a good agreement with the certified values at confidence interval of 95 %. The method was successfully applied to determination of Ag(I) and Cd(II) in several dried nut and vegetable samples by FAAS after separation/preconcentration with UA-CPE. © 2016, Springer Science+Business Media New York.en_US
dc.description.sponsorshipAltunay, N.; Faculty of Science, Department of Chemistry, University of CumhuriyetTurkey; email: naltunay@cumhuriyet.edu.tren_US
dc.language.isoengen_US
dc.relation.isversionof10.1007/s12161-016-0505-7en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAg(I)en_US
dc.subjectCd(II)en_US
dc.subjectDried nuts/vegetablesen_US
dc.subjectFlame atomic absorption spectrometryen_US
dc.subjectPreconcentrationen_US
dc.titleCombination of Ultrasonic-Assisted Cloud Point Extraction with Flame AAS for Preconcentration and Determination of Trace Amounts of Silver and Cadmium in Dried Nut and Vegetable Samplesen_US
dc.typearticleen_US
dc.relation.journalFood Analytical Methodsen_US
dc.contributor.departmentGürkan, R., Faculty of Science, Department of Chemistry, University of Cumhuriyet, Sivas, 58140, Turkey -- Altunay, N., Faculty of Science, Department of Chemistry, University of Cumhuriyet, Sivas, 58140, Turkey -- Yıldırım, E., Faculty of Science, Department of Chemistry, University of Cumhuriyet, Sivas, 58140, Turkeyen_US
dc.identifier.volume9en_US
dc.identifier.issue11en_US
dc.identifier.endpage3229en_US
dc.identifier.startpage3218en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record