Show simple item record

dc.contributor.authorÖzgüven Y.
dc.contributor.authorYaray K.
dc.contributor.authorAlkaya F.
dc.contributor.authorYücel B.
dc.contributor.authorSoyuer S.
dc.date.accessioned2019-07-27T12:10:23Z
dc.date.accessioned2019-07-28T09:32:15Z
dc.date.available2019-07-27T12:10:23Z
dc.date.available2019-07-28T09:32:15Z
dc.date.issued2014
dc.identifier.issn1507-1367
dc.identifier.urihttps://dx.doi.org/10.1016/j.rpor.2013.10.008
dc.identifier.urihttps://hdl.handle.net/20.500.12418/5497
dc.descriptionUrban and Partneren_US
dc.description.abstractAim: The purpose of the present study is to show the application of the IAEA TRS-430 QA procedures of Eclipse™v7.5 TPS for photon energies. In addition, the trends of the deviations found in the conducted tests were determined. Background: In the past, the lack of complete TPS QA procedures led to some serious accidents. So, QA in the radiotherapy treatment planning process is essential for determination of accuracy in the radiotherapy process and avoidance of treatment errors. Materials and methods: The calculations of TPS and measurements of irradiations of the treatment device were compared in the study. As a result, the local dose deviation values (?1: central beam axis, ?2: penumbra and build up region, ?3: inside field, ?4: outside beam edges, ?50-90: beam fringe, RW50: radiological width) and their confidence limit values (including systematic and random errors) were obtained. Results: The confidence limit values of ?4 were detected to increase with expanding field size. The values of ?1 and ?3 of hard wedge were larger than open fields. The values of ?2 and ?50-90 of the inhomogeneity effect test were larger, especially than other tests of this study. The average deviation was showed to increase with the rise of the wedge angle. The values of ?3 and ?4 of lung irradiation were outside tolerance. Conclusions: The QA of TPS was done and it was found that there were no reservations in its use in patient treatment. The trend of the deviations is shown. © 2013 Greater Poland Cancer Centre.en_US
dc.description.sponsorshipTSY-09-1047en_US
dc.description.sponsorshipScientific Research Project Fund of Erciyes University (Project Code: TSY-09-1047) (only dosimetric equipment support).en_US
dc.description.sponsorshipÖzgüven, Y.; Department of Radiation Oncology, Cumhuriyet University, Faculty of Medicine, TR-58140 Sivas, Turkey; email: yildq@hotmail.comen_US
dc.language.isoengen_US
dc.relation.isversionof10.1016/j.rpor.2013.10.008en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectConfidence limiten_US
dc.subjectLocal dose deviationen_US
dc.subjectPhoton beamen_US
dc.subjectQuality assuranceen_US
dc.subjectTreatment planning systemen_US
dc.titleAn institutional experience of quality assurance of a treatment planning system on photon beamen_US
dc.typearticleen_US
dc.relation.journalReports of Practical Oncology and Radiotherapyen_US
dc.contributor.departmentÖzgüven, Y., Department of Radiation Oncology, Cumhuriyet University, Faculty of Medicine, TR-58140 Sivas, Turkey -- Yaray, K., Department of Radiation Oncology, Erciyes University, Faculty of Medicine, TR-38039 Kayseri, Turkey -- Alkaya, F., Department of Radiation Oncology, Medicana Hospital, TR-34520 Istanbul, Turkey -- Yücel, B., Department of Radiation Oncology, Cumhuriyet University, Faculty of Medicine, TR-58140 Sivas, Turkey -- Soyuer, S., Department of Radiation Oncology, Erciyes University, Faculty of Medicine, TR-38039 Kayseri, Turkeyen_US
dc.identifier.volume19en_US
dc.identifier.issue3en_US
dc.identifier.endpage205en_US
dc.identifier.startpage195en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record