Show simple item record

dc.contributor.authorTopcuoglu T.
dc.contributor.authorBicakci A.A.
dc.contributor.authorAvunduk M.C.
dc.contributor.authorSahin Inan Z.D.
dc.date.accessioned2019-07-27T12:10:23Z
dc.date.accessioned2019-07-28T09:32:25Z
dc.date.available2019-07-27T12:10:23Z
dc.date.available2019-07-28T09:32:25Z
dc.date.issued2013
dc.identifier.issn1537744X
dc.identifier.urihttps://dx.doi.org/10.1155/2013/396091
dc.identifier.urihttps://hdl.handle.net/20.500.12418/5538
dc.description.abstractIntroduction. The aim of this study was to analyze the effects of screw design and force application on the stability of miniscrews, using RTT, SEM, and histomorphometric analyses. Materials and Methods. Eighty cylindrical, self-drilling, and Ti6Al4V alloy miniscrews (1,6 × 6 mm) were used. Four mini-screws were inserted in fibulas of each rabbit, and 115 G of force was immediately applied. Four miniscrews were inserted in the other fibula, on which no force was applied. Eight weeks after insertion, osseointegration between miniscrew and the surrounding bone was evaluated by the histomorphometric analyses, SEM, and RTT. Kruskal-Wallis and the paired t-tests were used for statistical analysis. Results. Values obtained from Group I were significantly higher than those of the other loaded groups (P <.05). There were no differences in RTT scores among Groups II, III, and IV. Similar findings were also observed for unloaded mini-screws. There was no significant difference between Groups I and IC, while the differences between loaded and unloaded controls for each miniscrew were statistically significant. Conclusions. Immediate loading of miniscrews does not impair screw stability. Also, the diameter of miniscrew and more frequent thread pitches have a positive effect on stability; however, length of miniscrews does not have a significant effect on the stability. © 2013 Tolga Topcuoglu et al.en_US
dc.description.sponsorshipTopcuoglu, T.; Department of Orthodontics, School of Dentistry, University of Gaziantep, Sehitkamil, 27310 Gaziantep, Turkey; email: dentisttolga@hotmail.comen_US
dc.language.isoengen_US
dc.relation.isversionof10.1155/2013/396091en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleEvaluation of the effects of different surface configurations on stability of miniscrewsen_US
dc.typearticleen_US
dc.relation.journalThe Scientific World Journalen_US
dc.contributor.departmentTopcuoglu, T., Department of Orthodontics, School of Dentistry, University of Gaziantep, Sehitkamil, 27310 Gaziantep, Turkey -- Bicakci, A.A., Department of Orthodontics, School of Dentistry, University of Cumhuriyet, 58000 Sivas, Turkey -- Avunduk, M.C., Department of Pathology, Meram Medical Faculty, University of Selcuk, 42030 Konya, Turkey -- Sahin Inan, Z.D., Department of Histology and Embryology, School of Medicine, 58000 Sivas, Turkeyen_US
dc.identifier.volume2013en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record