Basit öğe kaydını göster

dc.contributor.authorGürkan R.
dc.contributor.authorKartal Temel N.
dc.date.accessioned2019-07-27T12:10:23Z
dc.date.accessioned2019-07-28T09:32:57Z
dc.date.available2019-07-27T12:10:23Z
dc.date.available2019-07-28T09:32:57Z
dc.date.issued2019
dc.identifier.issn0306-7319
dc.identifier.urihttps://dx.doi.org/10.1080/03067319.2019.1632302
dc.identifier.urihttps://hdl.handle.net/20.500.12418/5661
dc.description.abstractIn the current study, a simple and low- cost method of UA-CPE in combination with flame atomic absorption spectrometry (FAAS) was developed for pre-concentration and indirect determination of melamine in milk-based samples. The method is based on the formation of charge transfer sensitive ternary complex among melamine, Mn(II) and Eosin Yin presence of sensitivity enhancer, ionic surfactant cetyltrimethylammonium bromide at pH 4.5, and then extraction of the formed complex into the micellar phase of nonionic surfactant, Triton X-114. After extraction, the surfactant-rich phase was diluted with 1.0 mol L?1 HNO3 in methanol and aspirated into the nebuliser of FAAS for indirect analysis. For optimisation of the variables affecting the ion-pair formation and extraction efficiency, the univariate method was adopted due to its simplicity and ease of use. Under optimal conditions, a good linear relationship was observed from 0.8 to 130 µg L?1 with a detection limit of 0.23 µg L?1. From pre-concentration of 35-mL sample, a pre-concentration factor of 70-fold was obtained with a good sensitivity enhancement (88.5). The accuracy and precision were evaluated as repeatability and intermediate precision with RSD of less than 6.5% with a recovery varied from 92.5% to 98.6%. (n: 5, 5, 25 and 100 µg L?1). The performance of the method from the accuracy and precision studies of two quality control samples was highly good with the precision (4.2–6.0%) and relative recoveries (91.4–96.0%) obtained for spiking levels, 5 and 10 µg L?1. The accuracy, according to two-way ANOVA analysis, was also controlled by two calibrations approaches without any matrix effect in analysis step of samples. © 2019, © 2019 Informa UK Limited, trading as Taylor & Francis Group.en_US
dc.language.isoengen_US
dc.publisherTaylor and Francis Ltd.en_US
dc.relation.isversionof10.1080/03067319.2019.1632302en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectEosin Yen_US
dc.subjectFAASen_US
dc.subjectMelamineen_US
dc.subjectmilk based samplesen_US
dc.subjectMn(II)en_US
dc.subjectUA-CPEen_US
dc.titleManganese sensitised-indirect determination of melamine in milk-based samples by flame atomic absorption spectrometry coupled with ultrasound assisted-cloud point extractionen_US
dc.typearticleen_US
dc.relation.journalInternational Journal of Environmental Analytical Chemistryen_US
dc.contributor.departmentGürkan, R., Faculty of Sciences, Department of Chemistry/Analytical Chemistry, University of Cumhuriyet, Sivas, Turkey -- Kartal Temel, N., Faculty of Sciences, Department of Chemistry/Analytical Chemistry, University of Cumhuriyet, Sivas, Turkeyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster