dc.contributor.author | Kaval, Mehmet Emin | |
dc.contributor.author | Akin, Hakan | |
dc.contributor.author | Guneri, Pelin | |
dc.date.accessioned | 2019-07-27T12:10:23Z | |
dc.date.accessioned | 2019-07-28T09:40:52Z | |
dc.date.available | 2019-07-27T12:10:23Z | |
dc.date.available | 2019-07-28T09:40:52Z | |
dc.date.issued | 2017 | |
dc.identifier.issn | 1059-941X | |
dc.identifier.issn | 1532-849X | |
dc.identifier.uri | https://dx.doi.org/10.1111/jopr.12386 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12418/6734 | |
dc.description | WOS: 000405822000016 | en_US |
dc.description | PubMed ID: 26513716 | en_US |
dc.description.abstract | Purpose: To evaluate the radiopacity of five post materials using a digital image analysis method. Materials and Methods: Twelve specimens from each post type (two zirconia and three fiber based) of 2 mm in thickness were obtained using a diamond blade mounted on a cutting machine, and digital radiographs were taken along with aluminum step-wedge and dentin discs under standard exposure conditions. The mean gray-values of specimens were measured using a computer graphics program. Data were analyzed using one-way ANOVA followed by Holm-Sidak multicomparison test (p = 0.05). Results: The highest radiopacity was observed in custom zirconia (5.842 millimeters of equivalent Al [mmAl]), and the lowest value was detected with FRC-Postec (Ivoclar Vivadent) (1.716 mmAl). Significant differences were revealed between the radiopacity values among all groups (p < 0.05), except the Zr post materials (p = 0.56). Conclusions: All tested post materials had higher radiopacity than dentin. Further studies will be required to clarify optimum radiopacity properties of the post materials to provide a precise clinical observation. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | WILEY | en_US |
dc.relation.isversionof | 10.1111/jopr.12386 | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Radiopacity | en_US |
dc.subject | fiber post | en_US |
dc.subject | quartz post | en_US |
dc.subject | zirconium dioxide | en_US |
dc.title | Radiopacity of Esthetic Post Materials: Evaluation with Digital Analysis Technique | en_US |
dc.type | article | en_US |
dc.relation.journal | JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | en_US |
dc.contributor.department | [Kaval, Mehmet Emin] Ege Univ, Sch Dent, Dept Endodontol, Izmir, Turkey -- [Akin, Hakan] Cumhuriyet Univ, Dept Prosthodont, Fac Dent, TR-58140 Sivas, Turkey -- [Guneri, Pelin] Ege Univ, Sch Dent, Dept Oral & Maxillofacial Radiol, Izmir, Turkey | en_US |
dc.identifier.volume | 26 | en_US |
dc.identifier.issue | 5 | en_US |
dc.identifier.endpage | 459 | en_US |
dc.identifier.startpage | 455 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |