Basit öğe kaydını göster

dc.contributor.authorAltunay, Nail
dc.contributor.authorGurkan, Ramazan
dc.contributor.authorOrhan, Ulas
dc.date.accessioned2019-07-27T12:10:23Z
dc.date.accessioned2019-07-28T09:47:47Z
dc.date.available2019-07-27T12:10:23Z
dc.date.available2019-07-28T09:47:47Z
dc.date.issued2015
dc.identifier.issn1944-0049
dc.identifier.issn1944-0057
dc.identifier.urihttps://dx.doi.org/10.1080/19440049.2015.1067725
dc.identifier.urihttps://hdl.handle.net/20.500.12418/7722
dc.descriptionWOS: 000360912600010en_US
dc.descriptionPubMed ID: 26160373en_US
dc.description.abstractA new ultrasonic-assisted cloud-point-extraction (UA-CPE) method was developed for the pre-concentration of Cu(II) in selected beverage and food samples prior to flame atomic absorption spectrometric (FAAS) analysis. For this purpose, Safranin T was used as an ion-pairing reagent based on charge transfer in the presence of oxalate as the primary chelating agent at pH 10. Non-ionic surfactant, poly(ethyleneglycol-mono-p-nonylphenylether) (PONPE 7.5) was used as an extracting agent in the presence of NH4Cl as the salting out agent. The variables affecting UA-CPE efficiency were optimised in detail. The linear range for Cu(II) at pH 10 was 0.02-70 mu gl(-)(1) with a very low detection limit of 6.10 ng l(-)(1), while the linear range for Cu(I) at pH 8.5 was 0.08-125 mu gl(-)(1) with a detection limit of 24.4 ng l(-)(1). The relative standard deviation (RSD %) was in the range of 2.15-4.80% (n = 5). The method was successfully applied to the quantification of Cu(II), Cu(I) and total Cu in selected beverage and food samples. The accuracy of the developed method was demonstrated by the analysis of two standard reference materials (SRMs) as well as recoveries of spiked samples.en_US
dc.language.isoengen_US
dc.publisherTAYLOR & FRANCIS LTDen_US
dc.relation.isversionof10.1080/19440049.2015.1067725en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectFAASen_US
dc.subjectSafranin Ten_US
dc.subjectUA-CPEen_US
dc.subjectfood safetyen_US
dc.subjectcopperen_US
dc.subjectfood/beveragesen_US
dc.titleA new ultrasonic-assisted cloud-point-extraction procedure for pre-concentration and determination of ultra-trace levels of copper in selected beverages and foods by flame atomic absorption spectrometryen_US
dc.typearticleen_US
dc.relation.journalFOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENTen_US
dc.contributor.department[Altunay, Nail -- Gurkan, Ramazan -- Orhan, Ulas] Cumhuriyet Univ, Dept Chem, Fac Sci, Sivas, Turkeyen_US
dc.identifier.volume32en_US
dc.identifier.issue9en_US
dc.identifier.endpage1487en_US
dc.identifier.startpage1475en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US