Show simple item record

dc.contributor.authorAltunbas, D.
dc.contributor.authorKustarci, A.
dc.contributor.authorArslan, D.
dc.contributor.authorEr, K.
dc.date.accessioned2019-07-27T12:10:23Z
dc.date.accessioned2019-07-28T09:56:46Z
dc.date.available2019-07-27T12:10:23Z
dc.date.available2019-07-28T09:56:46Z
dc.date.issued2014
dc.identifier.issn1119-3077
dc.identifier.urihttps://dx.doi.org/10.4103/1119-3077.144382
dc.identifier.urihttps://hdl.handle.net/20.500.12418/8124
dc.descriptionWOS: 000346005100008en_US
dc.descriptionPubMed ID: 25385906en_US
dc.description.abstractObjectives: The aim of this study was to evaluate the accuracy of four electronic apex locators (EALs) (DentaPort ZX, Raypex 5, Endo Master and VDW Gold) in detecting the major foramen using the clearing technique. Materials and Methods: Forty-eight extracted single-rooted extracted teeth with mature apices were used for the study and divided into four groups of 12 teeth each. All teeth were embedded in an alginate model. Electronic measurements were taken using a size 15 K-file attached to the holder. Then, the teeth were cleared and photographed under a stereomicroscope with a digital camera. The distance between the tip of the file and the major foramen was measured by using an image analysis software program. Positive and negative values were recorded when the file tip was beyond or short of the major foramen and zero value when the file tip and the major foramen coincided. Statistical analysis was performed using the Kruskal-Wallis and Chi-square tests at a significance level of 0.05. Results: Mean distance from the file tip to the major foramen were 0.302 0.202, 0.065 0.293, 0.117 0.475, and 0.258 0.160 mm in the DentaPort ZX, Raype 5, Endo Master, and VDW Gold groups, respectively. There were no statistically significant differences among the devices (P > 0.05) . Conclusion: Under the experimental conditions, all EALs showed an acceptable determination of the major foramen.en_US
dc.language.isoengen_US
dc.publisherMEDKNOW PUBLICATIONS & MEDIA PVT LTDen_US
dc.relation.isversionof10.4103/1119-3077.144382en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectClearing techniqueen_US
dc.subjectelectronic apex locatoren_US
dc.subjectmajor foramenen_US
dc.titleIn vitro comparison of four different electronic apex locators to determine the major foramen using the clearing techniqueen_US
dc.typearticleen_US
dc.relation.journalNIGERIAN JOURNAL OF CLINICAL PRACTICEen_US
dc.contributor.department[Altunbas, D.] Cumhuriyet Univ, Fac Dent, Dept Endodont, Sivas, Turkey -- [Kustarci, A. -- Er, K.] Akdeniz Univ, TR-07058 Antalya, Turkey -- [Arslan, D.] Bezmialem Vakif Univ, Istanbul, Turkeyen_US
dc.contributor.authorIDEr, Kursat -- 0000-0002-0667-4909;en_US
dc.identifier.volume17en_US
dc.identifier.issue6en_US
dc.identifier.endpage710en_US
dc.identifier.startpage706en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record