Arşiv logosu
  • English
  • Türkçe
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • English
  • Türkçe
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Guner, Aylin" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Küçük Resim Yok
    Öğe
    Push-out bond strength of Biodentine, MTA repair HP, and a new pre-mixed NeoPutty bioactive cement: scanning electron microscopy energy dispersive X-ray spectroscopy analysis
    (Springer, 2022) Ipek, Irem; Unal, Murat; Guner, Aylin; Candan, Merve
    The aim of this research was to evaluate the push-out bond strengths (PBSs) of three different calcium silicate-based cements abbreviated as Group 1 (NeoPutty), Group 2 (Biodentine), and Group 3 (MTA Repair HP). 15 root slices of 1 +/- 0.1-mm thickness were obtained from the middle triad of the roots of 5 maxillary premolar teeth. In each slice, three canal-like cavities parallel to the root canal were created for the experimental groups (n = 15). After endodontic irrigation, Group 1: NeoPutty, Group 2: Biodentine, and Group 3: MTA Repair HP were placed to the cavities, randomly. After the PBS test, all samples were examined scanning electron microscope (SEM) to determine failure patterns. To evaluate the chemical composition of the materials, three samples, one from each group, were prepared. Samples were prepared using plexiglass molds of 10-mm diameter and 2-mm thickness. The materials were then examined by an energy-dispersive X-ray spectroscopy (EDX, Inca, Oxford Inst.) for surface element analysis. The values obtained from tests were evaluated statistically significant (p < 0.05). After the PBS test, while there was no statistically significant difference between NeoPutty and MTA Repair HP, there was a difference with Biodentine. Based on the findings from this study, it was concluded that Biodentine has the highest PBS values.

| Sivas Cumhuriyet Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Kütüphane ve Dokümantasyon Daire Başkanlığı, Sivas, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim