Arşiv logosu
  • English
  • Türkçe
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • English
  • Türkçe
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Gurdal, Fatih" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Küçük Resim Yok
    Öğe
    Comparison of Intraocular Pressure and PachymeterMeasurements Obtained by Non Contact Tonometerpachymeterwith Goldmann Applanation Tonometer andCorneal Topography
    (2021) Yeter, Duygu Yalınbas; Koylu, Mehmet Talay; Oguz, Yeşim Gedık; Yesıltas, Yagmur Seda; Akıncıoglu, Dorukcan; Gurdal, Fatih; Mutlu, Fatih Mehmet
    Purpose: To compare the measurements of intraocular pressure (IOP) and central corneal thickness (CCT) by tono-pachymeter (CT-1P) with\rIOP measurements by Goldmann applanation tonometer (GAT), and CCT measurements by Pentacam.\rMaterials and Methods: Two hundred eighteen eyes of 109 patients were included in the study. Intraocular pressure measurements were\robtained by the CT-1P and GAT, whereas CCT measurements were obtained by CT-1P and Pentacam. Blant-Altman plots for agreement, and\rPearson correlation and interclass correlation (ICC) for reliability between the measurements were analyzed.\rResults: The mean IOPCT-1P, IOPCT-1P adj., IOPGAT were measured as 18.2±4.32 mmHg, 17.75±4.05 mmHg and 16.9±4.16 mmHg, respectively.\rThe mean CCT was measured as 554.8±37.3 ?m and 543.6±35.9 ?m with CT-1P and Pentacam, respectively. Mean differences between\rdevices were signifi cantly different in terms of IOP and CCT measurement (p<0.001, for all). Interclass correlation coeffi cient confi rmed the\rexcellent reliability between devices in terms of measurement of IOP and CCT (p<0.001, for all). The 95% limits of agreement (LoA) for IOP\rwere -4.24 to 3.28 mmHg between IOPCT-1P adj. and IOPCT-1P, -3.49 to 5.14 mmHg between IOPCT-1P adj. and IOPGAT and -2.7 to 5.3 mmHg between\rIOPCT-1P and IOPGAT. Also 95% LoA for CCT were -12.33 to 32.16 ?m between CCTCT-1P and CCTPentacam.\rConclusion: Although CT-1P overestimated both IOP and CCT measurements, the device had an excellent ICC with Pentacam and GAT in\rterms of CCT and IOP measurements. The ability of tono-pachymeters measuring both CCT and IOP with a single device provide an important\rconvenience in busy clinics.

| Sivas Cumhuriyet Üniversitesi | Kütüphane | Açık Erişim Politikası | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Kütüphane ve Dokümantasyon Daire Başkanlığı, Sivas, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim