Effect of Self-Cured and Self-Etch Adhesive Systems on Shear Bond Strength After Photodynamic Therapy and Disinfection with Different Types of Lasers

dc.contributor.authorÇeşme, Ayşe
dc.contributor.authorHubbezoğlu, İhsan
dc.date.accessioned2025-05-04T16:25:06Z
dc.date.available2025-05-04T16:25:06Z
dc.date.issued2023
dc.departmentSivas Cumhuriyet Üniversitesi
dc.descriptionDIS290
dc.description.abstractEffect of Self-Cured and Self-Etch Adhesive System on Shear Bond Strength After Photodynamic Therapy and Disinfection with Different Types of Lasers Ayşe Çeşme1-a*, Ihsan Hubbezoğlu1-b 1 Sivas Cumhuriyet University, Faculty of Dentistry, Department of Restorative Dentistry Sivas, Türkiye. ABSTRACT Objectives: The aim of this study was to investigate the strength of shear bonding of self-cured and self-etch adhesive systems to dentin after surface disinfection with Photodynamic Therapy (PDT), Er:YAG, Nd:YAG, and KTP laser. Materials and Methods: In the study, 6 main-groups were formed as Control, Er:YAG Laser, Nd: YAG Laser, KTP Laser, KTP Laser activated PDT and Diode Laser activated PDT. Each group was divided into two subgroups; Self-cured (Tokuyama Universal) and self-etch (Scotchbond Universal) adhesive system(n=10). 120 molar teeth were prepared to expose dentin surfaces. After disinfection and adhesive application, nanohybrid composite resin with a diameter of 3 mm and a height of 2 mm was applied to the dentin surface with the help of transparent molds. All samples were thermally cycled 5.000 times at 5°C and 55°C. Shear bond strength (SBS) test was applied to the samples in a universal test device. Results: The differences between the Er:YAG laser group and the control, KTP and Nd:YAG laser groups of the self-cured adhesive samples were statistically significant. While the differences between the Nd:YAG laser group and the PDT groups were statistically significant (p
dc.description.abstract[No abstract available]
dc.description.sponsorshipCUBAP
dc.identifier.doi10.7126/cumudj.1299029
dc.identifier.doihttps://doi.org/10.7126/cumudj.1299029
dc.identifier.endpage172
dc.identifier.issn1302-5805
dc.identifier.issn2146-2852
dc.identifier.issue2
dc.identifier.startpage164
dc.identifier.urihttps://hdl.handle.net/20.500.12418/32705
dc.identifier.volume26
dc.language.isoen
dc.publisherSivas Cumhuriyet Üniversitesi
dc.relation.ispartofCumhuriyet Dental Journal
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_DergiPark_20250504
dc.subjectphotodynamic therapy
dc.subjectself-cured adhesive
dc.subjectlaser disinfection
dc.subjectbond strength
dc.titleEffect of Self-Cured and Self-Etch Adhesive Systems on Shear Bond Strength After Photodynamic Therapy and Disinfection with Different Types of Lasers
dc.typeResearch Article

Dosyalar

Koleksiyon