Show simple item record

dc.contributor.authorOzdemir, Buelent
dc.contributor.authorBicer, Murat
dc.contributor.authorOzdemir, Levent
dc.contributor.authorBaran, Ibrahim
dc.contributor.authorKaderli, Aysel Aydin
dc.contributor.authorSenturk, Tunay
dc.contributor.authorEmul, Ali
dc.contributor.authorYetgin, Zeynel Abidin
dc.contributor.authorGullulu, Suemeyye
dc.contributor.authorAydinlar, Ali
dc.date.accessioned2019-07-27T12:10:23Z
dc.date.accessioned2019-07-28T10:14:25Z
dc.date.available2019-07-27T12:10:23Z
dc.date.available2019-07-28T10:14:25Z
dc.date.issued2009
dc.identifier.issn1749-8090
dc.identifier.urihttps://dx.doi.org/10.1186/1749-8090-4-14
dc.identifier.urihttps://hdl.handle.net/20.500.12418/10171
dc.descriptionWOS: 000265140600001en_US
dc.descriptionPubMed ID: 19323814en_US
dc.description.abstractBackground: Aortic distensibility is an elasticity index of the aorta, and reflects aortic stiffness. Coronary artery disease has been found to be substantially associated with increased aortic stiffness. In this study we aimed to retrospectively analyze the association of angiographically determined aortic distensibility with the patency rates of coronary bypass grafts Methods: The study was conducted in the Cardiology department of the Applied Research Centre for Health of Uludag University. The coronary angiograms of 53 consecutive coronary bypass patients were analysed retrospectively. Aortic distensibility was calculated using the formula: 2 x (change in aortic diameter)/(diastolic aortic diameter) x (change in aortic pressure). The number of stenosed and patent bypass grafts and the patient characteristics like age, risk factors were noted. Results: There were 44 male (83%) and 9 female (17%) cases. Eighteen cases had only one saphenous vein grafting. The number of cases with two, three and four saphenous grafting were 18, 11 and 1; respectively. In the control angiograms the number of cases with one, two, three and four saphenous vein graft obstruction were 15 (31.3%), 7 (14.6%), 1 (2.1%) and 1 (2.1%) respectively. The aortic distensibility did not differ in cases with and without saphenous graft occlusion (p > 0.05). Also left internal mammary artery (LIMA) graft patency was not related to the distensibility of the aorta (p > 0.05). We also evaluated the data for cut-off values of 50 and 70 mmHg of pulse pressure and did not see any significant difference between the groups in terms of saphenous or LIMA grafts. Conclusion: In this study we failed to show association of angiographically determined aortic distensibility with coronary bypass graft patency in consecutive 53 patients with coronary artery bypass graft surgery (CABG).en_US
dc.language.isoengen_US
dc.publisherBMCen_US
dc.relation.isversionof10.1186/1749-8090-4-14en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleAortic distensibility and coronary artery bypass graft patencyen_US
dc.typearticleen_US
dc.relation.journalJOURNAL OF CARDIOTHORACIC SURGERYen_US
dc.contributor.department[Ozdemir, Buelent -- Baran, Ibrahim -- Kaderli, Aysel Aydin -- Senturk, Tunay -- Emul, Ali -- Yetgin, Zeynel Abidin -- Gullulu, Suemeyye -- Aydinlar, Ali] Uludag Univ, Fac Med, Dept Cardiol, Gorukle, Bursa, Turkey -- [Bicer, Murat] Uludag Univ, Fac Med, Dept Cardiovasc Surg, Gorukle, Bursa, Turkey -- [Ozdemir, Levent] Cumhuriyet Univ, Fac Med, Dept Publ Hlth, Sivas, Turkeyen_US
dc.identifier.volume4en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record