Show simple item record

dc.contributor.authorTozum, TF
dc.contributor.authorHatipoglu, H
dc.contributor.authorYamalik, N
dc.contributor.authorGursel, M
dc.contributor.authorAlptekin, NO
dc.contributor.authorAtaoglu, T
dc.contributor.authorMarakoglu, I
dc.contributor.authorGursoy, UK
dc.contributor.authorEratalay, K
dc.date.accessioned2019-07-27T12:10:23Z
dc.date.accessioned2019-07-28T10:22:33Z
dc.date.available2019-07-27T12:10:23Z
dc.date.available2019-07-28T10:22:33Z
dc.date.issued2004
dc.identifier.issn0022-3484
dc.identifier.issn1600-0765
dc.identifier.urihttps://dx.doi.org/10.1111/j.1600-0765.2004.00758.x
dc.identifier.urihttps://hdl.handle.net/20.500.12418/11155
dc.descriptionWOS: 000223471100009en_US
dc.descriptionPubMed ID: 15324356en_US
dc.description.abstractBackground and objectives: Various methodological factors may operate during clinical gingival crevicular fluid (GCF) sampling, volume quantification or subsequent laboratory analysis. For precise volume quantification, specific concern for generation and maintenance of a reliable calibration curve, the potential risk of GCF loss as a result of evaporation or fluid retention on actual volume and the impact of local conditions is needed because each of these factors may act as a source of subsequent volumetric distortions. Thus, the present study aimed to analyse the impact of sample transfer time on the rate of evaporation and the possibility of fluid retention, and the impact of local conditions and number of replicated measurements on the reliability of calibration data. Materials and methods: To analyse evaporative errors, standardized Periopaper((R)) strips provided with known test volumes (0.1 mul, 0.2 mul, 0.5 mul and 0.6 mul) were transferred to Periotron 8000((R)) with different time intervals (immediately, 5 s, 30 s and 60 s). For fluid retention, after quantifying the actual volume of the strips provided with known volumes (0.1 mul and 0.6 mul) of two test fluids, a second set of measurements was performed using dry strips. To determine the impact of local conditions (temperature and humidity) and the validity of 3, 5 and 20 replications (0.0-0.6 mul with 0.1-mul increments) on device calibration for 20degreesC and 25degreesC, electronic readings were obtained from three devices at three different locations. Differences in volumetric data in each experimental design were statistically analysed. Results: No significant fluid loss was observed within 5 s, but evaporation clearly led to volumetric distortions with extending transfer times (30 s or 60 s) (p < 0.05). Measurable amounts of fluid retention were found for both volumes and both test fluids, but not with identical patterns. Local conditions resulted in unique calibration data for each test volume and for each device. Although a 5degreesC increase generally provided higher readings, this was not observed for all devices at all volumes. Additional replicates (n = 5 or n = 20) did not seem to add any further reliability to the triplicate scores for the given test volumes. Conclusion: The findings of the present study confirm the reliability of triplicate readings, and uniqueness of each device and electronic data and the distinct impact of local environmental conditions on the generation/maintenance of calibration scores for each particular device. Furthermore, they underline time-dependent evaporation and fluid retention as additional technical concerns and once again highlight the importance of methodological standardization of the electronic volume quantification process.en_US
dc.language.isoengen_US
dc.publisherWILEYen_US
dc.relation.isversionof10.1111/j.1600-0765.2004.00758.xen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectcalibrationen_US
dc.subjectevaporationen_US
dc.subjectgingival crevicular fluiden_US
dc.subjectPeriotronen_US
dc.subjectvolumeen_US
dc.titleCritical steps in electronic volume quantification of gingival crevicular fluid: the potential impact of evaporation, fluid retention, local conditions and repeated measurementsen_US
dc.typearticleen_US
dc.relation.journalJOURNAL OF PERIODONTAL RESEARCHen_US
dc.contributor.departmentHacettepe Univ, Fac Dent, Dept Periodontol, TR-06100 Ankara, Turkey -- Selcuk Univ, Fac Dent, Dept Periodontol, Konya, Turkey -- Cumhuriyet Univ, Fac Dent, Dept Periodontol, Sivas, Turkeyen_US
dc.contributor.authorIDTOZUM, TOLGA -- 0000-0002-1667-622X; Alptekin, Nilgun Ozlem -- 0000-0003-4104-6462; Gursoy, Ulvi Kahraman -- 0000-0002-1225-5751en_US
dc.identifier.volume39en_US
dc.identifier.issue5en_US
dc.identifier.endpage357en_US
dc.identifier.startpage344en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record