Show simple item record

dc.contributor.authorTas, F
dc.contributor.authorCeran, C
dc.contributor.authorAtalar, MH
dc.contributor.authorBulut, S
dc.contributor.authorSelbes, B
dc.contributor.authorIsik, AO
dc.date.accessioned2019-07-27T12:10:23Z
dc.date.accessioned2019-07-28T10:22:41Z
dc.date.available2019-07-27T12:10:23Z
dc.date.available2019-07-28T10:22:41Z
dc.date.issued2004
dc.identifier.issn0720-048X
dc.identifier.urihttps://dx.doi.org/10.1016/S0720-048X(03)00145-1
dc.identifier.urihttps://hdl.handle.net/20.500.12418/11192
dc.descriptionWOS: 000222396600015en_US
dc.descriptionPubMed ID: 15186891en_US
dc.description.abstractPurpose: In this prospective study we aimed to investigate the diagnostic value of ultrasonography (US) in hemodynamically stable children after blunt abdominal trauma (BAT) using computed tomography (CT) as the gold standard. Materials and methods: Between 1997 and 200 1, 96 children with BAT were evaluated prospectively. CT was performed first, followed by US. US and CT examinations were independently evaluated by two radiologists for free fluid and organ injury. The sensitivity, specificity, positive predictive value, negative predictive value and overall accuracy of US were assessed regarding CT as the gold standard. Results: Overall 128 organ injuries were determined in 96 patients with CT; however, 20 (15.6%) of them could not be seen with US. Free intraabdominal fluid (FIF) was seen in 82 of 96 patients by CT (85.4%) and eight of them (9.7%) could not be seen by US. We found that sensitivity, specificity, positive predictive value, negative predictive value and overall accuracy of the US for free intra-abdominal fluid were 90.2, 100, 100, 63.6 and 91.7%, respectively. Conclusions. US for BAT in children is highly accurate and specific. It is highly sensitive in detecting liver, spleen and kidney injuries whereas its sensitivity is moderate for the detection of gastrointestinal tract (GIT) and pancreatic injuries. (C) 2003 Published by Elsevier Ireland Ltd.en_US
dc.language.isoengen_US
dc.publisherELSEVIER SCI IRELAND LTDen_US
dc.relation.isversionof10.1016/S0720-048X(03)00145-1en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectblunt abdominal traumaen_US
dc.subjectultrasonographyen_US
dc.subjectcomputed tomographyen_US
dc.subjectchildrenen_US
dc.titleThe efficacy of ultrasonography in hemodynamically stable children with blunt abdominal trauma: a prospective comparison with computeden_US
dc.typearticleen_US
dc.relation.journalEUROPEAN JOURNAL OF RADIOLOGYen_US
dc.contributor.departmentCumhuriyet Univ, Fac Med, Dept Radiol, TR-58140 Sivas, Turkey -- Cumhuriyet Univ, Fac Med, Dept Pediat Surg, TR-58140 Sivas, Turkeyen_US
dc.identifier.volume51en_US
dc.identifier.issue1en_US
dc.identifier.endpage96en_US
dc.identifier.startpage91en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item