Show simple item record

dc.contributor.authorAdil Elik
dc.contributor.authorMehmet Akçay
dc.date.accessioned23.07.201910:49:13
dc.date.accessioned2019-07-23T16:20:33Z
dc.date.available23.07.201910:49:13
dc.date.available2019-07-23T16:20:33Z
dc.date.issued1999
dc.identifier.issn1300-1949
dc.identifier.urihttp://www.trdizin.gov.tr/publication/paper/detail/TXpRMU1UYzM=
dc.identifier.urihttps://hdl.handle.net/20.500.12418/1258
dc.description.abstractBu çalışmada, üzerinde özel bir kuruluşa ait selestisit zenginleştirme tesisi bulunan ırmak sedimentinde stronsiyum iyonunun miktarı, hareketi ve bağlanma biçimlerinin ardışık özütleme tekniğiyle belirlenmesi amaçlanmıştır. Irmak üzerinde seçilen örnekleme istasyonlarından alınan sedimentlerde stronsiyum fraksiyonları(adsorbe, karbonat, oksit, organik ve mineral bağlı) Tessier ardışık özütleme metodu ile özütlenmiştir. Ayrıca her bir istasyon örneğinde toplam metal özütlenmesi de yapılmıştır. Özütlerden stronsiyum matriks düzenleyici olarak önerilen %1 $La^{+3}$ eklenerek, atomik absorpsiyon spektrometresi(AAS) ile belirlenmiştir. Kirletici kaynaktan hemen sonra ırmak sedimentindeki toplam stronsiyum özgün sedimentteki miktarının 22 katı fazla bulunmuştur. Kirletici kaynaktan uzaklaşıldıkça; organik ve karbonat bağlı stronsiyumda düzenli bir düşüş, oksit bağlı stronsiyumda önce hafif bir artış ve sonra hızlı bir düşüş, mineral bağlı stronsiyumda hafif bir artış görülmüştür. Adsorbe bağlı stronsiyumda ise uzaklıkla belirgin bir artış görülmekle birlikte değişim bir düzenlilik göstermemektedir. Yöntemin kesinliği ortalama bağıl standart sapma (BSS%) cinsinden, adsorbe, karbonat, oksit, organik ve mineral bağlı fraksiyonlar için sırasıyla % 12.4 (n=24), % 9.7 (n=24), % 14.2 ( n=21), % 12.2 (n=21) ve % 23.5 (n=21) değerlerinde bulunmuştur.en_US
dc.description.abstractIn this study, it was aimed that amount, mobility and bonding types of strontium in river sediment which have had selestisid mine drainage area were determined by sequential extraction method. The strontium fractions such as adsorbed, carbonate, oxide, organic and mineral bounded in sediment which was sampling on river were extracted by Tessier sequential extraction method. In addition, the each station sample was also extracted for total metal. Sr in the extracts in which was added 1% $La^{+3} was determined by atomic absorption spectrometer (AAS).Total Sr in river sediment which is immediate vicinity of pollutant source is 22 times greater than in sediment collected before from drainage water disposal site. It was seen that as a while distance from drainage water disposal site; the organic and carbonate bounded Sr gradually decreased; the oxide bounded Sr slightly increased before and than speedy decreased; the mineral bounded Sr slightly increased; change at the adsorbed Sr was not shown regularity together gradually increased. The precision of method in terms of average relative standard deviation % (RSD%) for adsorbe, carbonate, oxide, organic and mineral bounded fractions 12.4 % (n=24), 9.7 % (n=24), 14.2 % (n=21), 12.2 % (n=21) and 23.5 % (n=21), respectively.en_US
dc.language.isoturen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectMühendisliken_US
dc.subjectOrtak Disiplinleren_US
dc.titleIrmak sedimentinde stronsiyum iyonu fraksiyonlarının ardışık özütleme tekniğiyle belirlenmesien_US
dc.title.alternativeDetermination of strontium fractions in river sediment by sequential extraction methoden_US
dc.typeotheren_US
dc.relation.journalCumhuriyet Üniversitesi Fen-Edebiyat Fakültesi Fen Bilimleri Dergisien_US
dc.contributor.departmentSivas Cumhuriyet Üniversitesien_US
dc.identifier.volume21en_US
dc.identifier.issue2en_US
dc.identifier.endpage175en_US
dc.identifier.startpage169en_US
dc.relation.publicationcategoryDiğeren_US]


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record