dc.contributor.author | Fulya Köybaşıoğlu | |
dc.contributor.author | Semra Özakkoyunlu | |
dc.contributor.author | Sinan Kocatürk | |
dc.contributor.author | Üzmez Binnur Önal | |
dc.date.accessioned | 23.07.201910:49:13 | |
dc.date.accessioned | 2019-07-23T16:22:15Z | |
dc.date.available | 23.07.201910:49:13 | |
dc.date.available | 2019-07-23T16:22:15Z | |
dc.date.issued | 2004 | |
dc.identifier.uri | http://www.trdizin.gov.tr/publication/paper/detail/TlRBMU1qazU= | |
dc.identifier.uri | https://hdl.handle.net/20.500.12418/1570 | |
dc.description.abstract | Giriş: Bu çalışma baş-boyun bölgesi yerleşimli palpabl kitlelerin tanısında ince iğne aspirasyon sitolojisi’nin (İİAS) sensitivite, spesifisite ve doğruluk değerlerinin saptanması amacıyla yapılmıştır. Materyal ve Yöntem: SSK Ankara Eğitim Hastanesi Patoloji Kliniği Sitoloji Ünitesinde 2001-2003 yılları arasında baş-boyun kitlesi olan toplam 369 hastaya İİAS uygulanmıştır. Sonuçlar: Bu 369 hastadan histopatolojik değerlendirmesi patoloji kliniğimiz kayıtlarında bulunan toplam 83 olgu değerlendirmeye alınmıştır. Anatomik yerleşim yerlerine göre dağılım yapılmaksızın İİAS ve histopatolojik sonuçların uyumuna göre sensitivite % 93.4, spesifisite % 81.8, doğruluk değerleri % 88.8 olarak bulunmuştur. Tartışma: Baş boyun kitlelerinin ve tiroidin nodüler lezyonlarının İİAS benign-malign ayırımında faydalı birinci basamak tanı yöntemidir. | en_US |
dc.description.abstract | Aim: This study aims to define the sensitivity, specificity and accuracy values of fine needle aspiration cytology (FNAC) in diagnosis of palpable head and neck masses. Material and Methods: FNAC was applied to 369 patient with head and neck masses at Cytology Unit of Pathology Dept. in the SSK Training & Research Hospital, between years of 2001-2003. Results: Among 369 , 83 cases with histopathologic specimens examined in our department were studied. According to the correlation between FNAC and histopathologic examination results, the sensitivity, specificity and accuracy values were defined as 93.4%, 81.8% and 88.8% respectively, without considering the different anotomic localization of the masses. Discussion: FNAC is proved to be the first step diagnostic procedure in differential diagnosis of benign and malignant lesions in head- neck masses and thyroid nodules. | en_US |
dc.language.iso | tur | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Kulak | en_US |
dc.subject | Burun | en_US |
dc.subject | Boğaz | en_US |
dc.title | Baş boyun kitlelerindeki ince iğne aspirasyon sitolojisi sonuçlarımız | en_US |
dc.title.alternative | The results of fine needle aspiration cytology in the head and neck masses | en_US |
dc.type | article | en_US |
dc.relation.journal | KBB-Forum | en_US |
dc.contributor.department | Sivas Cumhuriyet Üniversitesi | en_US |
dc.identifier.volume | 3 | en_US |
dc.identifier.issue | 2 | en_US |
dc.identifier.endpage | 34 | en_US |
dc.identifier.startpage | 31 | en_US |
dc.relation.publicationcategory | Makale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı | en_US] |