Show simple item record

dc.contributor.authorSemra Özdemir
dc.contributor.authorTaner Erselcan
dc.contributor.authorZekiye Hasbek
dc.contributor.authorİzzet Tandoğan
dc.contributor.authorCesur Gümüş
dc.date.accessioned23.07.201910:49:13
dc.date.accessioned2019-07-23T16:27:17Z
dc.date.available23.07.201910:49:13
dc.date.available2019-07-23T16:27:17Z
dc.date.issued2011
dc.identifier.issn1305-0028
dc.identifier.urihttp://www.trdizin.gov.tr/publication/paper/detail/TVRjMU5qTXdNQT09
dc.identifier.urihttps://hdl.handle.net/20.500.12418/2026
dc.description.abstractBu makalede Talyum-201(Tl-201) ile yapılan miyokard perfüzyon sintigrafisi sırasında tesadüfen saptanan bir vaka sunuldu. Stres ve rest SPECT projeksiyonlarının değerlendirilmesi esnasında ilk 10 projeksiyon görüntüsünde orta mediastende ve sağ akciğer alanında geniş bir foton defektli alan izlendi. Yapılan tomografide hastanın da haberdar olmadığı Morgagni tipte bir diafragmatik herni saptandı. Büyük boyutlu bu kitlenin kardiak aktiviteyi engelleyeceği, kardiak kesitlerde önemli defektler yaratabileceği ve yanlış sonuçlara neden olabileceği düşünüldü. Bundan dolayı kitlenin kalp üzerindeki attenüasyon etkisini engelleyebilecek farklı açıda yeni bir rest çekimi yapıldı. Ancak ilginç olarak bu iki farklı rest çalışma sonuçları arasında anlamlı bir fark izlenmedi. Diğer taraftan bu vaka, MPS çalışmasının tüm verilerinin incelenmesinin raslantısal tanıdaki önemini bize hatırlatmaktadır.en_US
dc.description.abstractA case of diaphragmatic hernia, detected incidentally by Thallium 201 (Tl-201) myocardial perfusion scintigraphy (MPS), was presented. We recognized a large photon deficient area in the right lung and middle mediastinum regions, also attenuating cardiac activity in the first 10 projections during the evaluation of stress and rest single-photon emission computed tomography (SPECT) projections of the subject. Computed tomography (CT) examination of the mass revealed a diaphragmatic hernia of Morgagni type of from which the patient was unaware. We thought that this huge mass would have mask cardiac activity and cause important defects in cardiac sections and thus might lead to false results. Therefore, another rest examination was performed with a different acquisition angles that would avoid the attenuating effect of the mass on the heart. However, no substantial difference was observed, interestingly, between the outcomes of these two data sets. On the other hand presented case reminds that it is important to examine whole data set of a MPS study for incidental diagnosis.en_US
dc.language.isoengen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectCerrahien_US
dc.titleIncidentally detected large diaphragmatic hernia in Tl-201 myocardial perfusion scintigraphy; no substantial effect on the study resultsen_US
dc.title.alternativeMiyokard p erf üzyon sintigraf isinde tesadüf en sap tanan ve çalışma sonuçlarını etkilemeyen büyük boyutlu bir diaf ragmatik hernien_US
dc.typearticleen_US
dc.relation.journalCumhuriyet Tıp Dergisi (ELEKTRONİK)en_US
dc.contributor.departmentSivas Cumhuriyet Üniversitesien_US
dc.identifier.volume33en_US
dc.identifier.issue4en_US
dc.identifier.endpage491en_US
dc.identifier.startpage487en_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US]


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record