dc.contributor.author | Koray Soygun | |
dc.contributor.author | Arife Kaplan | |
dc.contributor.author | Giray Bolayır | |
dc.date.accessioned | 23.07.201910:49:13 | |
dc.date.accessioned | 2019-07-23T16:32:36Z | |
dc.date.available | 23.07.201910:49:13 | |
dc.date.available | 2019-07-23T16:32:36Z | |
dc.date.issued | 2014 | |
dc.identifier.issn | 1302-5805 | |
dc.identifier.uri | http://www.trdizin.gov.tr/publication/paper/detail/TVRjMU5qVXhNUT09 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12418/2525 | |
dc.description.abstract | Amaç: Farklı sürelerde ozon uygulanan PMMA yüzeylerinin yumuşak astar materyali ile yaptığı bağlantı dayanımına etkisini araştırmakdır. Gereç ve Yöntem: Bu çalışmada yumuşak astar materyali olan Molloplast-B (Detax, Ettlingen, Germany) ve protez kaide materyali ısıyla polimerize edilen PMMA (Meliodent, Bayer Dental, Newbury, UK) akrilik rezin kullanıldı. 4 örnek grubu ve her bir grup için 5 örnek hazırlandı. Grup 2, 3 ve 4 örnek gruplarına sırasıyla 40, 80, 120 sn ozon gazı uygulaması yapıldı. Grup 1 kontrol grubu olarak değerlendirildi. Bulgular: 120 sn ozon uygulanan grup 4 en düşük bağlantı dayanım 28,60±1,51 değerine sahiptir. Ve diğer gruplar arasında farklılık önemli bulunmuştur (p<0,05). Sonuç: Test grupları arasında Ozon gazı uygulanmayan grup 1 en yüksek bağlantı dayanım 40.40±3.50 değerine sahiptir. PMMA yüzeylerine ozon uygulama süresi arttıkça örnek grupların bağlantı dayanım değerlerinde düşüş olduğu görüldü. | en_US |
dc.description.abstract | Objectives: To investigate the effects of application of ozone with different durations on the bond strength between PMMA and soft liner material. Materials and Methods: The soft liner tested in this study was a heat processed silicone-based material, Molloplast B (ML) (Detax, Ettlingen, Germany), and the denture base material was a heat-cured poly (methyl methacrylate) (PMMA) acrylic resin material (Meliodent, Bayer Dental, Newbury, UK). Four sample groups were formed and each of them consisted of 5 specimens. Groups of 2, 3, and 4 were performed ozone gaseous 40, 80,120 s respectively. But not group 1. Results: Group 4 revealed the lowest strength 28.60±1.51, being statistically different from those of the specimens in the other groups (p<0.05). Conclusions: Group 1 (untreatment ozone gaseous) offered the best tensile bond strength 40.40±3.50 values among the tested groups. As increasing ozone treatment duration to PMMA surface, decreasing tensile bond strength of sample groups. | en_US |
dc.language.iso | tur | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Diş Hekimliği | en_US |
dc.title | Yumuşak astar ve PMMA arasındaki çekme bağlantı dayanımına ozon gaz etkisi | en_US |
dc.title.alternative | Effect of ozone gaseous to tensile bond strength between soft liner and PMMA | en_US |
dc.type | article | en_US |
dc.relation.journal | Cumhuriyet Dental Journal | en_US |
dc.contributor.department | Sivas Cumhuriyet Üniversitesi | en_US |
dc.identifier.volume | 17 | en_US |
dc.identifier.issue | 3 | en_US |
dc.identifier.endpage | 222 | en_US |
dc.identifier.startpage | 215 | en_US |
dc.relation.publicationcategory | Makale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı | en_US] |