Show simple item record

dc.contributor.authorKoray Soygun
dc.contributor.authorMurat Ünal
dc.contributor.authorAli Özer
dc.contributor.authorEvrem Gülnahar
dc.contributor.authorGiray Bolayır
dc.date.accessioned23.07.201910:49:13
dc.date.accessioned2019-07-23T16:32:37Z
dc.date.available23.07.201910:49:13
dc.date.available2019-07-23T16:32:37Z
dc.date.issued2014
dc.identifier.issn1302-5805
dc.identifier.urihttp://www.trdizin.gov.tr/publication/paper/detail/TVRjMU5UWTFOUT09
dc.identifier.urihttps://hdl.handle.net/20.500.12418/2533
dc.description.abstractAmaç: Bu çalış ma üç farklı bulk fill kompozit (Surefil SDR flow, Dentsply, Caulk, USA and Tetric, EvoCeram, Ivoclar Vivadent, Schaan, Liechtenstein, X-tra base, Voco, Cuxhaven, Germany) mikrosertliklerinin araş tırılmasıdır. Gereç ve Yöntem: Çalış ma için 4mm ve 2mm kalınlığ ında 4mm yarı çapında hazırlanan herbir bulk fill kompozit Plama ark ış ık kayanağ ı kullanılarak polimerize edildi. Her bir örneğ in alt ve üst mikrosertlik değ erlendirmeleri Vickers mikrosertlik test cihazı kullanılarak yapıldı Bulgular: Çalış mada kullanılan tüm materyallerin polimerizasyonu ış ık kaynağ ı ile yapıldıktan sonra alt yüzeylere ait sertlik değ eri üst yüzeylerden daha düş ük bulundu. Tüm komozitler arasında en yüksek Vickers sertlik değ eri (40.02±4.06) olan grup, üst Xtra base bulk fill kompozitine aitdir. En düş ük Vickers sertlik değ eri (5.80±0.83) alt ölçüm yapılan SDR bulk fill grubuna aittir. Sonuçlar: Tüm gruplara ait sertlik oranı 0.80 den daha düş ük bulundu. Gruplara ait sertlik oranı 0,19±0,3 ile 0,72±0,06 arasında tespit edildi.en_US
dc.description.abstractObjectives: This study was examined the surface microhardness of three kind of bulk fill composites Surefil SDR flow, Tetric, EvoCeram, X-tra base) Materials and Methods: Ten specimens of 2mm, 4mm thickness and 4mm diameter of each bulk fill composite were polymerized using a halogen light and a blue light-emitted diode. Microhardness evaluation was performed at the top and bottom surfaces for each specimen using a Vickers microhardness tester. Results: All of the materials were cured with the light sources and the values obtained for the bottom surfaces were found to be lower than the values of top surfaces. Highest microhardness level (40.02±4.06) among all composite materials belonged to Xtra base composite group, whereas lowest microhardness level (5.80±0.83) was of SDR composite specimens. Conclusions: Hardness ratio range was between 0.19±0.3 and 0.72±0.06. Hardness ratio value was found to be lower than 0.80 for all composite groups.en_US
dc.language.isoturen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectDiş Hekimliğien_US
dc.titleFarklı akış kan bulk fill kompozitlerin mikrosertliklerinin araş tırılmasıen_US
dc.title.alternativeAn investigation of microhardness cured different flow bulk fill compositesen_US
dc.typearticleen_US
dc.relation.journalCumhuriyet Dental Journalen_US
dc.contributor.departmentSivas Cumhuriyet Üniversitesien_US
dc.identifier.volume17en_US
dc.identifier.issue1en_US
dc.identifier.endpage69en_US
dc.identifier.startpage64en_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US]


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record