Show simple item record

dc.contributor.authorİrem Gül Sancak
dc.contributor.authorÖzge Özdemir
dc.contributor.authorSinan Ulusan
dc.contributor.authorHasan Bilgili
dc.date.accessioned23.07.201910:49:13
dc.date.accessioned2019-07-23T16:32:41Z
dc.date.available23.07.201910:49:13
dc.date.available2019-07-23T16:32:41Z
dc.date.issued2014
dc.identifier.issn1300-0861
dc.identifier.urihttp://www.trdizin.gov.tr/publication/paper/detail/TVRVM05EUTRPQT09
dc.identifier.urihttps://hdl.handle.net/20.500.12418/2575
dc.description.abstractBu çalışma kedilerde Sirküler Eksternal Fiksatör tekniğinin kullanımını değerlendirmektedir. Çalışmanın konusunu özel olarak dizayn edilmiş Sirküler Eksternal Fiksatör kullanarak tibia kırıkları sağaltılan 7 kedi oluşturmuştur. Bütün tibia kırıkları cerrahi olarak sağaltılmıştır. Olguların kontrolleri; post operatif 25. ve 48. günlerde radyografik olarak yapılmıştır. Hastanın eşgali, kırığın lokalizasyonu, komplikasyonlar ve implant çapları not edilmiştir. Halka çapları 5 olguda 45 mm ve 2 olguda 55 mm olarak tercih edilmiştir. CEF sistemi postoperatif takip döneminde bütün kediler tarafından iyi tolere edilmiştir. Tedavi edilen ekstremitenin ilk kullanımı tüm olgularda ameliyat sonrası 1-3 günde gerçekleşmiştir. Pin deformasyon veya CEF’te kırılma ve bozulma olguların hiçbirinde gözlenmemiştir. 2 kedide pin dibi enfeksiyonu komplikasyonu ile karşılaşılmıştır. 5 olguda sonuçlar mükemmel 2 olguda ise iyi olarak değerlendirilmiştir. Sirküler Eksternal Fiksatör sistemi kedi ekstremite kırıklarında kullanışlı bulunmuş ve meslektaşlarımıza tavsiye edilmektedir.en_US
dc.description.abstractThis study covers the technique of a custom designed circular external fixator (CEF) in tibial fractures in 7 cats. All tibial fractures were surgically treated. The cases were followed-up using radiographs obtained on 25 and 48 days after surgery. Signalment, fracture localization, complications and implant diameter for each cat were noted. Ring diameters were as follows: in 4 tibial fracture cases 45 mm and in 3 tibial fracture cases 55 mm. Complications were observed in 2 cats, both of which had pin tract infection. Fracture cases were evaluated as follows: 5 of the tibial fractures had excellent results and 2 cases had good results. The CEF system was well tolerated by all the cats during the postoperative follow-up period. First use of the treated limb occurred on postoperative 1-3 day in all cases. Pin deformation or CEF breakage and distortion were not observed in any of the cases. The CEF system designed by the authors was suitable for fixation of tibial fractures in cats. Clinical use of CEF system in tibial fractures of cats is found to be useful and its use is highly recommended to our colleagues.en_US
dc.language.isoengen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectVeterinerliken_US
dc.titleTreatment of tibial fractures in seven cats using circular external skeletal fixationen_US
dc.title.alternativeYedi kedide tibia kırıklarının sirküler eksternal fiksasyon kullanılarak sağaltımıen_US
dc.typearticleen_US
dc.relation.journalAnkara Üniversitesi Veteriner Fakültesi Dergisien_US
dc.contributor.departmentSivas Cumhuriyet Üniversitesien_US
dc.identifier.volume61en_US
dc.identifier.issue3en_US
dc.identifier.endpage178en_US
dc.identifier.startpage173en_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US]


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record