dc.description.abstractAmaç. Çok düzlemli kablo fiksasyon sisteminin biyomekanik dayanıklılığının araştırılması. Yöntem. Çalışmada 12 adet dana femur kemiğine subtrokanterik oblik osteotomi yapılarak standart kablo fiksasyon sistemi ve çok düzlemli kablo fiksasyon sistemi ile tespit edildikten sonra aksiyel kompresyon testleri uygulandı. Bulgular. Yöntemlere ait kompresyon kuvvet değerlerinin aritmetik ortalaması standart kablo fiksasyon sistemi için 787,33 N, çok düzlemli kablo fiksasyon sistemi için 1631,66 N olarak ölçüldü. Gruplara ait tespit yetersizliği ölçümleri karşılaştırıldığında gruplar arası farklılık anlamlı bulundu (p<0.05). Sonuç. Kırık yada osteotomi hattının çok düzlemli uzanımlarının önceden öngörülememesi, standart kablo fiksasyon sisteminin tek bir düzlemde fiksasyona izin vermesi ve metafizer metafizo-diafizer bölgede gevşemesi nedeni ile çok düzlemli kablo fiksasyon sistemi bu sorunların giderilmesinde mutlak bir üstünlük sağlamaktadır.en_US
dc.description.abstractAim. Research of bio-mechanical stability of multi-plane cable fixation system. Method. In this study, axial compression tests were applied, after 12 calf femur bone was fixed with standard cable fixation system and multi-plane cable fixation system by subtrochanteric osteotomy. Results. Arithmetic mean of compression force values of technics were measured for standard cable fixation system as 787,33 N, for multi-plane cable fixation system as 1631,66 N. When fixation nadequacy measurements was compared, difference of between groups shows correlation. (p&lt;0.05). Conclusion. Due to multi plane elongations of line of fracture or osteotomy can not be foreseen, standard cable fixation system allows fixation on a single plane and relaxed on metaphyseal metaphyso-diaphsial region, Multi-plane cable fixation system provides significant advantage in solving this problem.en_US
dc.language.isoturen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectCerrahien_US
dc.titleÇok düzlemli kablo fiksasyon sisteminin biyomekanik dayanıklılığının araştırılmasıen_US
dc.title.alternativeInvestigation of biomechanical stability of multi-plane cable f ixation systemen_US
dc.typearticleen_US
dc.relation.journalCumhuriyet Tıp Dergisi (ELEKTRONİK)en_US
dc.contributor.departmentSivas Cumhuriyet Üniversitesien_US
dc.identifier.volume35en_US
dc.identifier.issue4en_US
dc.identifier.endpage562en_US
dc.identifier.startpage555en_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US]


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record