dc.contributor.author | Oğuzhan Gürler | |
dc.contributor.author | Ali Kemal Özdemir | |
dc.date.accessioned | 23.07.201910:49:13 | |
dc.date.accessioned | 2019-07-23T16:33:19Z | |
dc.date.available | 23.07.201910:49:13 | |
dc.date.available | 2019-07-23T16:33:19Z | |
dc.date.issued | 2013 | |
dc.identifier.issn | 1302-5805 | |
dc.identifier.uri | http://www.trdizin.gov.tr/publication/paper/detail/TVRjMU9UY3dNQT09 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12418/2803 | |
dc.description.abstract | Amaç: Diş hekimliğ inde kullanımları giderek yaygınlaş an seromer grubundan Estenia düş ük ısı porseleninin, titanyum metal alt yapılarla farklı yüzey ş artlandırmalarında bağ lantı dayanımı değ erlendirmektir. Gereç ve Yöntem: Çalış mamızda titanyumdan ISO-9693:1999 standartlarına göre 25x3x0,5mm3 ebatlarında hazırlanan metal alt yapı örnekleri kullanıldı. Metal örnek yüzeylerine kumlama (n=12) ve Nd-YAG lazeri ile kumlama+lazer (n=12) uygulamaları yapılarak çalış ma grupları oluş turuldu. Üst yapı porseleni olarak seromer grubundan estenia düş ük ısı materyali 8x3x3mm3 ebatlarında metal alt yapı üzerine üretici firma talimatlarına uygun olacak ş ekilde uygulandı. Daha sonra örneklere, transvers dirençlerinin tespit edilmesi amacıyla üniversal test cihazında üç nokta bükme testi uygulandı. Cihazın yük uygulama hızı 0,5 mm/dak ve çeneler arası mesafe 20mm olacak ş ekilde ayarlandı. Örnek gruplarında porselenin metal alt yapıdan ayrıldığ ı andaki bağ lantı dayanım değ erleri N/mm2 türünden kaydedildi. Elde edilen verilerin değ erlendirilmesinde Mann-Whitney U testi kullanıldı. Bulgular: Kumlama ve kumlama+lazer uygulanan örnekler kıyaslandığ ında, kumlama+lazer gruplarında bağ lantı dayanımı yönünden istatistiksel anlamlı bir fark izlenmedi. (p>0,05). Sonuç: Titanyum metal alt yapılara bağ lantı dayanımı yönünden yeterli seviyede olduğ u belirlenen estenia materyalinin, yüksek ısı porselenlerine ciddi bir alternatif olabileceğ i tespit edildi. Bununla birlikte Nd:YAG lazer uygulamasının titanyum yüzey bağ lantı değ erlerini artırdığ ı ancak istatistiksel olarak anlamlı bir fark oluş turmadığ ı belirlendi. | en_US |
dc.description.abstract | Objectives: To investigate bond strength between Estenia, is a kind of seromer has been increasingly used in dentistry, low fusing porcelain and titanium metal sub-structures after different surface treatments. Materials and Methods: In the present study, ISO9693:1999 standards 25x3x0.5mm3 dimensions of the samples used prepared with titanium in the metal substructure. Metal sample surface blasting (n=12) and Nd-YAG laser with a blasting + laser (n=12) by application of the working groups were formed. Low-temperature materials as porcelain superstructure estenia seromer group size 8x3x3mm3 metal substructure to be applied according to the instructions of the manufacturer. Later examples, universal testing device to determine the three-point transverse fracture resistance test was performed. Unit load application rate of 0.5 mm/min and the distance between the jaws adjusted to 20 mm. Example of porcelain metal sub-structure, divided into groups, the type of the current connection N/mm2 strength values were recorded. Mann-Whitney U test was used for the evaluation of the data obtained. Results: Titanium metal sub-structures in terms of strength of connection estenia material determined to be sufficient, can be a serious alternative to high temperature porcelains were detected. However, the Nd: YAG laser irradiation of titanium surface connection values were determined in a value increase, but statistically not significant. Conclusion: Blasting and sandblasting + samples compared to laser therapy, sand blasting + laser groups showed no statistically significant differences in terms of connection strength. (p>0.05). | en_US |
dc.language.iso | tur | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Diş Hekimliği | en_US |
dc.title | Porselen ile titanyumun bağ lanma dayanımına Nd-YAG lazerin etkinliğ inin incelenmesi | en_US |
dc.title.alternative | Study of the Nd-YAG laser effectiveness for Connection strength of titanium to porcelain | en_US |
dc.type | article | en_US |
dc.relation.journal | Cumhuriyet Dental Journal | en_US |
dc.contributor.department | Sivas Cumhuriyet Üniversitesi | en_US |
dc.identifier.volume | 16 | en_US |
dc.identifier.issue | 3 | en_US |
dc.identifier.endpage | 180 | en_US |
dc.identifier.startpage | 174 | en_US |
dc.relation.publicationcategory | Makale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı | en_US] |