Show simple item record

dc.contributor.authorBurak Buldur
dc.contributor.authorFatih Oznurhan
dc.contributor.authorMevlut Kayabası
dc.contributor.authorFeride Sahın
dc.date.accessioned23.07.201910:49:13
dc.date.accessioned2019-07-23T16:37:13Z
dc.date.available23.07.201910:49:13
dc.date.available2019-07-23T16:37:13Z
dc.date.issued2018
dc.identifier.issn1302-5805
dc.identifier.urihttp://www.trdizin.gov.tr/publication/paper/detail/TWpjMU5UUTFOUT09
dc.identifier.urihttps://hdl.handle.net/20.500.12418/3265
dc.description.abstractAmaç: Bu in vitro çalışmanın amacı, Biodentine® ve Imicrly MTA'nın bir kompomer materyaline makaslama bağlanma dayanımını karşılaştırmak ve farklı sertleşme sürelerinin bağlanma dayanımına olan etkisini incelemektir. Gereç ve Yöntem: Ortası delikli (4 mm çapında ve 2 mm yüksekliğinde) toplam 100 akrilik blok hazırlandı. Akrilik bloklar uygulanacak siman tipine göre rastgele iki ana gruba ayrıldı, Biodentine® veya Imicrly MTA (n = 50). Daha sonra, her bir ana grubun numuneleri, farklı sertleşme sürelerine göre rastgele seçilen 5 alt gruba ayrıldı. (12 dakika, 24 saat, 48 saat, 72 saat ve 96 saat) (n = 10). Numuneler, üreticinin talimatlarına göre tamamen Biodentine® veya Imicrly MTA ile dolduruldu. Kompomer materyali şeffaf tüp yardımıyla yerleştirildi ve kompomer LED cihazıyla (EliparTM, 3M ESPE, MN, ABD) 40 saniye ışıkla polimerize edildi. Akrilik kalıplar universal bir test makinesine sabitlendi ve kesme kuvveti 1 mm/dakika çapraz hızda olacak şekilde makaslama bağlanma dayanım (MBD) testi yapıldı. Veriler iki yönlü ANOVA ve Tukey's post-hoc testi ile analiz edildi (p = 0.05). Bulgular: Biodentine®'in 12 dk sertleşme süresinde Imicrly MTA'ya göre MBD değerlerinde anlamlı derecede yüksek iken (p<0.05) diğer ayar dönemleri arasında Biodentine® ile MTA arasında anlamlı fark yoktu (p>0.05). Test edilen simanlardan bağımsız olarak, sertleşme süreleri grupları arasındaki çift karşılaştırmalarda benzer MBD değerleri vardı (p>0.05). Sonuçlar: Tüm sertleşme zamanı gruplarında, Biodentine®'in kompomere olan bağlanma dayanım değerleri Imicrly MTA'ya göre daha yüksek görülürken, yalnızca istatistiksel anlamlılık 12 dakika sertleşme süresi grubunda mevcuttuen_US
dc.description.abstractObjectives: The purposes of this in vitro study was to compare the bond strength of Biodentine® and Imicryl MTA to a compomer material, and to examine the effect of the setting time on the bond strength. Materials and Methods: A total of 100 acrylic blocks with a hole (4 mm in diameter and 2 mm in height) were prepared. Acrylic blocks were randomly divided into two main groups according to cement type to be applied, Biodontine® or Imicryl MTA (n = 50). The specimens of each main group were then divided into 5 subgroups, which were randomized relative to different setting times. (12 minutes, 24 hours, 48 hours, 72 hours, and 96 hours) (n = 10). The samples were filled completely with Biodentine® or Imicrly MTA according to the manufacturer's instructions. Compomer was placed in this transparent tube with the help of a hand plugger and light cured for 40 seconds with the LED device (EliparTM, 3M ESPE, MN, USA) to polymerize the compomer. The acrylic molds were fixed to a universal test machine and shear bond strength (SBS) test was made under shear force at a cross-speed of 1 mm/min. Data were analyzed by a two-way ANOVA and Tukey’s posthoc test (p=0.05). Results: While, Biodentine® had significantly higher SBS values than Imicrly MTA at 12m setting time (p<0.05), there was no difference between Biodentine® and Imicrly MTA among other setting periods (p>0.05). Regardless of cements tested, there were similar SBS values among pairwise comparisons between setting time groups (p>0.05). Conclusions: There were higher SBS values of Biodentine® to compomer than Imicrly MTA in all setting time groups, the only statistical significance existed in 12 min groupen_US
dc.language.isoturen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectDiş Hekimliğien_US
dc.titleSHEAR BOND STRENGTH OF TWO CALCIUM SILICATE-BASED CEMENTS TO COMPOMERen_US
dc.title.alternativeKompomerin Kalsiyum Silikat Esaslı Simanlara Olan Makaslama Bağlanma Dayanımıen_US
dc.typearticleen_US
dc.relation.journalCumhuriyet Dental Journalen_US
dc.contributor.departmentSivas Cumhuriyet Üniversitesien_US
dc.identifier.volume21en_US
dc.identifier.issue1en_US
dc.identifier.endpage23en_US
dc.identifier.startpage18en_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US]