Show simple item record

dc.contributor.authorAdil Elik
dc.contributor.authorGültekin Gökçe
dc.contributor.authorÇağdaş Ceylan
dc.date.accessioned23.07.201910:49:13
dc.date.accessioned2019-07-23T16:37:54Z
dc.date.available23.07.201910:49:13
dc.date.available2019-07-23T16:37:54Z
dc.date.issued2017
dc.identifier.issn2587-2680
dc.identifier.urihttp://www.trdizin.gov.tr/publication/paper/detail/TWpjMU1qRTFOUT09
dc.identifier.urihttps://hdl.handle.net/20.500.12418/3559
dc.description.abstractBu çalışma, oldukça geniş bir konakçı gurubunda enfeksiyona yol açan bir patojen olan Anaplasma Phagocytophilum dizi seçimli DNA hibridizasyonunun voltametrik yöntemle tayin edildiği tek kullanımlık elektrokimyasal DNA biyosensörü geliştirilmesine yöneliktir. Herhangi bir etiketlemenin yapılmadığı bu elektrokimyasal çalışmanın esasını DNA hibridizasyonu sonrasında Guanin bazının yükseltgenme sinyalinin ölçülmesi ile bir dubleks oluşumunun izlenmesi oluşturur. Söz konusu biyosensör tasarımı inozinmodifiye (guanin içermeyen) probun, kalem grafit elektrota (PGE) immobilize edilmesi ve diferansiyel puls voltametrisi (DPV) ile guanin yükseltgenme sinyalinin ölçülerek, dubleks oluşumu tayinini içerir. Bu çalışmanın ilk aşamasında, Anaplasma phagocytophilum temsil eden prob dizisi, aktive edilmiş kalem grafit elektrot (PGE) yüzeyine yaş adsorbsiyon yöntemi ile immobilize edilmiş ve daha sonra prob ve hedefi arasındaki hibridizasyonun varlığı 1000 mV'da gözlenen guanin yükseltgenme sinyali ile tespit edilmiştiren_US
dc.description.abstractThis study was intended to enhance the disposable electrochemical DNA biosensor through which Anaplasma phagocytophilum, a pathogen causing infection in a considerably wide host group, sequence selective DNA hybridization was detected with a voltammetry method. Monitoring the formation of a duplex by measuring the oxidation signal of guanine base after DNA hybridization forms the basis of this study in which no labeling was done. The biosensor design contained immobilizing inosine modified (guanine-free) probe to the pencil graphite electrode (PGE) and detecting duplex formation by measuring guanine oxidation signal with differential pulse voltammetry (DPV). optimization study, it was observed that probe concentration was 25 µg/mL, immobilization time was 6 minutes; for the hybridization, target concentration was 40 µg/mL and hybridization time was 10 minutes. Selectivity of biochemical biosensor developed was tested by using mismatch and non complementary target sequences. It was also confirmed that DNA hybridization was carried out with impedimetric measurements by using electrochemical impedance method under the ferri/ferro cyanide redox system. To estimate the detection limit (DL), target sequences whose concentrations varies between 0, 78 µM and 3,90 µM were used, and it was found that the detection limit was 0,244 µMen_US
dc.language.isoturen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectMühendisliken_US
dc.subjectOrtak Disiplinleren_US
dc.titleAnaplasma Phagocytophilum’un Tayinine Yönelik Elektrokimyasal DNA Sensörü Geliştirilmesien_US
dc.title.alternativeDevelopment of Electrochemical DNA Sensor for The Determination of Anaplasma Phagocytophilumen_US
dc.typearticleen_US
dc.relation.journalCumhuriyet Science Journalen_US
dc.contributor.departmentSivas Cumhuriyet Üniversitesien_US
dc.identifier.volume38en_US
dc.identifier.issue4en_US
dc.identifier.endpage758en_US
dc.identifier.startpage748en_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US]