Show simple item record

dc.contributor.authorElik A.
dc.date.accessioned2019-07-27T12:10:23Z
dc.date.accessioned2019-07-28T09:12:42Z
dc.date.available2019-07-27T12:10:23Z
dc.date.available2019-07-28T09:12:42Z
dc.date.issued2005
dc.identifier.issn0039-9140
dc.identifier.urihttps://dx.doi.org/10.1016/j.talanta.2004.12.050
dc.identifier.urihttps://hdl.handle.net/20.500.12418/4450
dc.description.abstractA sample preparation method based on ultrasound assisted pseudo-digestion of Pb, Cu, Zn and Ni from street dust samples under ultrasonic effect has been described. Parameters influencing pseudo-digestion, such as sonication time, sample mass, particle size and solvent system were fully optimized. Final solutions obtained upon sonication were analyzed by atomic absorption spectrometry. The best conditions for metal pseudo-digestion were as follows: a 25 min sonication time, a 0.3 g sample mass (in 25 ml solvent), a particle size <63 ?m and a mixture of concentrated HNO3-HClO4-HF (2:1:1, v/v/v). Analytical results for the four metals by ultrasound assisted pseudo-digestion, acid bomb and conventional wet digestion methods showed a good agreement, thus indicating the possibility of using mild conditions for sample preparation instead of intensive treatments inherent with the digestion methods. In addition, this method reduces the time required for all treatments (pseudo-digestion or digestion, heating to dryness, cooling and separation) with acid bomb and conventional wet digestion methods approximately from 9 to 1 h. The accuracy of the method was tested either by comparing obtained results with those of acid bomb and conventional wet digestion methods or by application on two standard reference materials. The average relative standard deviation of ultrasound assisted pseudo-digestion method varied between 0.9 and 1.8% for N = 12, depending on the analyte. © 2004 Elsevier B.V. All rights reserved.en_US
dc.language.isoengen_US
dc.publisherElsevieren_US
dc.relation.isversionof10.1016/j.talanta.2004.12.050en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAASen_US
dc.subjectMetalsen_US
dc.subjectPseudo-digestionen_US
dc.subjectSample preparationen_US
dc.subjectStreet dusten_US
dc.subjectUltrasounden_US
dc.titleUltrasound assisted pseudo-digestion of street dust samples prior to determination by atomic absorption spectrometryen_US
dc.typearticleen_US
dc.relation.journalTalantaen_US
dc.contributor.departmentElik, A., Faculty of Art and Science, Department of Analytical Chemistry, University of Cumhuriyet, 58140 Sivas, Turkeyen_US
dc.identifier.volume66en_US
dc.identifier.issue4en_US
dc.identifier.endpage888en_US
dc.identifier.startpage882en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record