dc.description.abstractA sensitive and relatively selective spectrophotometric method is proposed for the rapid determination of uranium using Eriochrome Black T (EBT) being a 2, 2'-dihydroxy azo benzene derivative metal indicator in the presence of cationic surfactant of N-cetyl N, N, N-trimethylammonium bromide (CTAB). The complex formation reaction between EBT and uranyl ion, UO2 2+ is instantaneous in presence of NH3/NH4Cl buffer at pH 9.5 and the absorbance as analytical signal remains stable for over 6 h. CTAB as cationic surfactant and polyethylene glycol p-(1, 1, 3, 3-tetramethylbutyl)-phenyl ether, octyl phenol ethoxylate (Triton X-100) as nonionic surfactant are used for improving the sensitivity and solubility of the analytical system, respectively. The proposed method allows the determination of uranium in the concentration range of 0.025-2 ?g mL-1 with a molar absorption coefficient of 92440.60 L mol-1 cm-1 and Sandell's sensitivity of 2.92 ?g cm2- in micellar medium while it allows the determination of uranium in the concentration range of 0.25-2.5 ?g mL-1 with a molar absorption coefficient of 57019.44 L mol-1 cm-1 and Sandell's sensitivity of 4.74 ?g cm2- at 565 nm in water. The method has a detection limit of 4.60 ?g L-1 (CDL: 3Sb/m) at an analytical measurement wavelength of 637 nm with a bathochromic shift of 72 nm. The selectivity of chelating reagent was improved by the use of a mixture containing ethylenediaminetetraacetic acid (EDTA), sulfosalycylic acid and NaF as masking agent. The proposed method has been successfully applied to the determination of uranium at trace levels in different environmental water samples such as tap-water, natural spring-water and river-water. The precision (with coefficient of variation of 1.85%) and the accuracy obtained were highly satisfactory. In order to test the accuracy and validation of the method, the certified reference material (TMDA-70; fortified lake water sample) was also analyzed. It was found that the found and the certified values were in good agreement for validating the surfactant enhanced-spectrophotometric method. © 2011 Atlantis Livros Ltda. All rights reserved.en_US
dc.description.sponsorshipGürkan, R.; University of Cumhuriyet, Faculty of Sciences and Arts, Department of ChemistryTurkey; email: rgurkan@cumhuriyet.edu.tren_US
dc.language.isoengen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBathochromic shiften_US
dc.subjectCTABen_US
dc.subjectEBTen_US
dc.subjectSpectrophotometryen_US
dc.subjectSurfactantsen_US
dc.subjectUranium determinationen_US
dc.titleSurfactant enhanced-spectrophotometric determination of uranium (VI) at trace levels by using eriochrome black T as a chelating agenten_US
dc.typearticleen_US
dc.relation.journalEcletica Quimicaen_US
dc.contributor.departmentGürkan, R., University of Cumhuriyet, Faculty of Sciences and Arts, Department of Chemistry, Sivas, TR-58140, Turkey -- Ulusoy, H.I., University of Cumhuriyet, Faculty of Sciences and Arts, Department of Chemistry, Sivas, TR-58140, Turkey -- Akçay, M., University of Cumhuriyet, Faculty of Sciences and Arts, Department of Chemistry, Sivas, TR-58140, Turkeyen_US
dc.identifier.volume36en_US
dc.identifier.issue3en_US
dc.identifier.endpage46en_US
dc.identifier.startpage37en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US