Show simple item record

dc.contributor.authorTemel N.K.
dc.contributor.authorGürkan R.
dc.date.accessioned2019-07-27T12:10:23Z
dc.date.accessioned2019-07-28T09:31:29Z
dc.date.available2019-07-27T12:10:23Z
dc.date.available2019-07-28T09:31:29Z
dc.date.issued2016
dc.identifier.issn1759-9660
dc.identifier.urihttps://dx.doi.org/10.1039/c6ay01632d
dc.identifier.urihttps://hdl.handle.net/20.500.12418/5261
dc.descriptionRoyal Society of Chemistryen_US
dc.description.abstractA simple and low-cost catalytic spectrophotometric method using sodium dodecyl sulfate (SDS) as a sensitivity-improving surfactant to detect low levels of Mo(vi) in beverage matrices was developed. The method is based on the catalytic effect of molybdenum on the oxidation of 4,4?-(1,1-dioxido-3H-2,1-benzoxathiole-3,3-diyl)bis(2,6-dibromophenol) (bromophenol blue, HIn-) with H2O2 in the presence of SDS as a sensitizer in the premicellar region at pH 6.0. The surfactant-sensitive catalytic reaction was monitored by measuring the decrease in the absorbance at 590 nm after a fixed time of 5 min, which is linearly related to the molybdenum concentration in a wide working range. The optimal reaction conditions (e.g., surfactant concentration, reagent concentration and time) were evaluated and optimized, and then the analytical figures of the merit of the method (such as the limits of detection and quantification, linear working range, accuracy and precision) were established. Linearity was observed in a Mo(vi) ion concentration range of 5-150 ?g L-1, and the limits of detection and quantification of the method were 1.80 and 5.46 ?g L-1, respectively. The relative standard deviations (RSDs) and relative errors for the five replicate measurements of 25 and 100 ?g L-1 Mo(vi) were lower than 3.5% and 2.3%, respectively. The interference effect of some anions, cations and neutral species was also tested. The accuracy was controlled by the analysis of two certified samples, and the results were found statistically to be in good agreement with the certified values at a 95% confidence limit. The method was successfully applied to the catalytic determination of low levels of Mo(vi) in milk-based beverages. © 2016 The Royal Society of Chemistry.en_US
dc.description.sponsorshipTemel, N.K.; University of Cumhuriyet, Faculty of Sciences, Department of ChemistryTurkey; email: nkartal@cumhuriyet.edu.tren_US
dc.language.isoengen_US
dc.relation.isversionof10.1039/c6ay01632den_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.titleCatalytic spectrophotometric determination of trace Mo(VI) in milk-based beverages in the presence of bromophenol blue and H2O2 using SDS as a sensitizeren_US
dc.typearticleen_US
dc.relation.journalAnalytical Methodsen_US
dc.contributor.departmentTemel, N.K., University of Cumhuriyet, Faculty of Sciences, Department of Chemistry, Sivas, TR-58140, Turkey -- Gürkan, R., University of Cumhuriyet, Faculty of Sciences, Department of Chemistry, Sivas, TR-58140, Turkeyen_US
dc.identifier.volume8en_US
dc.identifier.issue33en_US
dc.identifier.endpage6292en_US
dc.identifier.startpage6284en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record