Show simple item record

dc.contributor.authorAltunay N.
dc.contributor.authorGürkan R.
dc.date.accessioned2019-07-27T12:10:23Z
dc.date.accessioned2019-07-28T09:31:47Z
dc.date.available2019-07-27T12:10:23Z
dc.date.available2019-07-28T09:31:47Z
dc.date.issued2015
dc.identifier.issn1936-9751
dc.identifier.urihttps://dx.doi.org/10.1007/s12161-015-0220-9
dc.identifier.urihttps://hdl.handle.net/20.500.12418/5352
dc.descriptionSpringer New York LLCen_US
dc.description.abstractA new micellar mediated cloud-point extraction procedure (CPE) has been developed for sensitive and selective determination of trace amounts of total iodine by means of indirect spectrophotometry. The method is based on selective charge transfer complex formation of I3, which is produced by the reaction of iodate in presence of 25-fold excess periodate with excess iodide and with acridine orange (AOH+) being a selective fluorescent cationic dye at pH 3.0 phthalate buffer, and then the CPE of charge transfer complex formed from aqueous solution at phthalate buffer using nonionic surfactant, Triton X-114. The calibration graphs were rectilinear in the ranges of 1.5-20 and 20-160 ?g L-1 for IO3 -, with r2 higher than 0.9996 in two linear regions with changing sensitivity. Under optimal conditions obtained, the limits of detection and quantification were 0.4 and 1.5 ?g L-1 and the precision (as RSD) for determination of 10, 50, and 100 ?g L-1 of iodate was in the range of 2.4-4.7% (n 5). The method was success- fully applied to selective and reliable determination of total iodine in milk-based nutritional products. The accuracy of the method was controlled by analyzing two standard reference materials (SRMs) at suitable matrix to milk samples. © Springer Science+Business Media New York 2015.en_US
dc.description.sponsorshipAltunay, N.; Department of Chemistry, University of CumhuriyetTurkey; email: naltunay@cumhuriyet.edu.tren_US
dc.language.isoengen_US
dc.relation.isversionof10.1007/s12161-015-0220-9en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAcridine orangeen_US
dc.subjectCloud-point extractionen_US
dc.subjectIodineen_US
dc.subjectMilken_US
dc.subjectReferencesen_US
dc.subjectSpectrophotopmetren_US
dc.titleA new micellar mediated cloud-point extraction procedure for sensitive and selective determination of trace amounts of total iodine in Milk-based nutritional products by means of indirect spectrophotometryen_US
dc.typearticleen_US
dc.relation.journalFood Analytical Methodsen_US
dc.contributor.departmentAltunay, N., Department of Chemistry, University of Cumhuriyet, Sivas, TR-58140, Turkey -- Gürkan, R., Department of Chemistry, University of Cumhuriyet, Sivas, TR-58140, Turkeyen_US
dc.identifier.volume9en_US
dc.identifier.issue2en_US
dc.identifier.endpage518en_US
dc.identifier.startpage505en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record