Show simple item record

dc.contributor.authorTemel N.K.
dc.contributor.authorSertakan K.
dc.contributor.authorGürkan R.
dc.date.accessioned2019-07-27T12:10:23Z
dc.date.accessioned2019-07-28T09:33:11Z
dc.date.available2019-07-27T12:10:23Z
dc.date.available2019-07-28T09:33:11Z
dc.date.issued2018
dc.identifier.issn0163-4984
dc.identifier.urihttps://dx.doi.org/10.1007/s12011-018-1337-7
dc.identifier.urihttps://hdl.handle.net/20.500.12418/5705
dc.description.abstractIn this study, ultrasound-assisted cloud point extraction (UA-CPE) method was developed for the determination of Ni(II) and Co(II) in milk-based products. After extraction and preconcentration, the Ni(II) and Co(II) contents of samples were determined by flame atomic absorption spectrometry (FAAS). After their complexation with hydroxy naphthol blue (HNB) in the presence of cationic surfactant, CTAB at pH 4.0, the Ni(II) and Co(II) were taken within the micellar phase of nonionic surfactant, TX-114. The micellar phase containing the analytes were diluted to a volume of 0.7 mL with 1.0-mol/L HNO3 in ethanol to reduce its viscosity and to facilitate sample treatment and then was analyzed by FAAS. The various analytical parameters affecting UA-CPE efficiency were investigated. The analytical features obtained after optimization are as follows: limits of detection are 0.56 and 0.78 ?g/L; sensitivity enhancement factors are 48.6 and 53.9; the calibration curves were linear 3-180 and 2-160 ?g/L for Co(II) and Ni(II), respectively, after preconcentration of 50-fold. The precision (as RSD%) between 1.8-3.6% and 2.2-3.8% (25 and 100 ?g/L, n?=?5) for Ni(II) and Co(II), respectively. The accuracy was statistically verified by analysis of two certified reference material samples (CRMs), including recovery studies after spiking. The method was applied to the analysis of milk-based samples with satisfied results. © Springer Science+Business Media, LLC, part of Springer Nature 2018.en_US
dc.language.isoengen_US
dc.publisherHumana Press Inc.en_US
dc.relation.isversionof10.1007/s12011-018-1337-7en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCobalten_US
dc.subjectFAASen_US
dc.subjectHydroxy naphthol blueen_US
dc.subjectMilk-based productsen_US
dc.subjectNickelen_US
dc.subjectTX-114en_US
dc.subjectUA-CPEen_US
dc.titlePreconcentration and determination of trace nickel and cobalt in milk-based samples by ultrasound-assisted cloud point extraction coupled with flame atomic absorption spectrometryen_US
dc.typearticleen_US
dc.relation.journalBiological Trace Element Researchen_US
dc.contributor.departmentTemel, N.K., Faculty of Sciences, Department of Chemistry, Analytical Chemistry University of Cumhuriyet, Sivas, TR-58140, Turkey -- Sertakan, K., Faculty of Sciences, Department of Chemistry, Analytical Chemistry University of Cumhuriyet, Sivas, TR-58140, Turkey -- Gürkan, R., Faculty of Sciences, Department of Chemistry, Analytical Chemistry University of Cumhuriyet, Sivas, TR-58140, Turkeyen_US
dc.identifier.volume186en_US
dc.identifier.issue2en_US
dc.identifier.endpage607en_US
dc.identifier.startpage597en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record