Show simple item record

dc.contributor.authorKulualp, Kadri
dc.contributor.authorYurdakul, Ibrahim
dc.contributor.authorErol, Hanifi
dc.contributor.authorAtalan, Gultekin
dc.contributor.authorKilic, Servet
dc.date.accessioned2019-07-27T12:10:23Z
dc.date.accessioned2019-07-28T09:37:49Z
dc.date.available2019-07-27T12:10:23Z
dc.date.available2019-07-28T09:37:49Z
dc.date.issued2018
dc.identifier.issn0025-8628
dc.identifier.urihttps://dx.doi.org/10.21521/mw.6024
dc.identifier.urihttps://hdl.handle.net/20.500.12418/6187
dc.descriptionWOS: 000442755200003en_US
dc.description.abstractThe current study was undertaken to establish reference values of intraocular pressure in clinically normal Turkish Shepherd Dogs with the rebound tonometer (TonoVet (R)) and the applanation tonometer (Tono-Pen Vet (R)). Twenty-eight dogs (14 male and 14 female, aged 9 months-9 years, 56 eyes) were used in this study. All animals were healthy and showed no abnormalities in ophthalmic examinations, which consisted of the Schirmer tear test, slit lamp bio-microscopy, and fluorescein staining. The animals were restrained manually without using systemic anesthetics or tranquilizers. IOP was measured in both eyes with a TonoVet (R) and a Tono-Pen Vet (R). In normal dogs, the mean IOP values for all eyes were 17.63 +/- 3.34 mmHg according to the TonoVet (R) and 14.95 +/- 2.92 mmHg according to the Tono-Pen Vet (R). There was no effect of sex, age, or eye side (right vs. left) on the results obtained with either the TonoVet (R) or the Tono-Pen Vet (R). The mean IOP obtained with the rebound tonometer was 2-3 mmHg higher than that measured with the applanation tonometer. The reference data obtained in the present study may assist in diagnostic testing for ophthalmic diseases in Turkish Shepherd Dogs and may promote further studies in this area.en_US
dc.language.isoengen_US
dc.publisherPOLISH SOC VETERINARY SCIENCES EDITORIAL OFFICEen_US
dc.relation.isversionof10.21521/mw.6024en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectapplanation tonometryen_US
dc.subjectrebound tonometryen_US
dc.subjectdogen_US
dc.subjecteyeen_US
dc.subjectintraocular pressureen_US
dc.titleMeasurement of intraocular pressure in clinically normal Turkish Shepherd Dogs with the rebound tonometer (TonoVet (R)) and the applanation tonometer (Tono-Pen Vet (R))en_US
dc.typearticleen_US
dc.relation.journalMEDYCYNA WETERYNARYJNA-VETERINARY MEDICINE-SCIENCE AND PRACTICEen_US
dc.contributor.department[Kulualp, Kadri] Firat Univ, Vocat Sch Hlth Serv, Elazig, Turkey -- [Yurdakul, Ibrahim] Cumhuriyet Univ, Fac Vet Med, Dept Vet Surg, Sivas, Turkey -- [Erol, Hanifi -- Atalan, Gultekin] Erciyes Univ, Fac Vet Med, Dept Vet Surg, Kayseri, Turkey -- [Kilic, Servet] Namik Kemal Univ, Fac Vet Med, Dept Vet Surg, Tekirdag, Turkeyen_US
dc.identifier.volume74en_US
dc.identifier.issue9en_US
dc.identifier.endpage573en_US
dc.identifier.startpage568en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record