Show simple item record

dc.contributor.authorAkis, Halil
dc.contributor.authorDoruk, Cenk
dc.date.accessioned2019-07-27T12:10:23Z
dc.date.accessioned2019-07-28T09:38:27Z
dc.date.available2019-07-27T12:10:23Z
dc.date.available2019-07-28T09:38:27Z
dc.date.issued2018
dc.identifier.issn2528-9659
dc.identifier.issn2148-9505
dc.identifier.urihttps://dx.doi.org/10.5152/TurkJOrthod.2018.17026
dc.identifier.urihttps://hdl.handle.net/20.500.12418/6345
dc.descriptionWOS: 000436159100002en_US
dc.descriptionPubMed ID: 30112507en_US
dc.description.abstractObjective: This study aimed to examine the biomechanical effects of the fixed functional appliances reinforced with miniscrews by finite elements analysis over the cranial and facial bones, temporomandibular joint, and maxillary-mandibular teeth, which are used for the treatment of Class II division 1 malocclusions characterized as mandibular retrognathia. Methods:Three-dimensional (3-D) models of the cranial, mandibular, and maxillary bones were purchased from a company that produces 3-D models of the bones. Simulations of Forsus, screwed Forsus, Twin-Force and screwed Twin-Force appliances were conducted on the 3-D models.The miniscrew was placed in the inter-radicular area between the upper canine and first upper premolar teeth. Results: It was observed in the models that the first upper molar tooth was the most affected. The compressive stress was observed in the anterior area of the mandibular condyle neck in the Forsus appliances; however, it was observed in the posterior area of the mandibular condyle neck in Twin-Force appliances. Conclusion: It was observed that molar distalization and expansion decreases in the functional appliances with the support of miniscrew. The highest tension rates were determined in the areas of condylar and articular discs.en_US
dc.language.isoengen_US
dc.publisherAVES PRESS LTDen_US
dc.relation.isversionof10.5152/TurkJOrthod.2018.17026en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectFunctional treatmenten_US
dc.subjectminiscrewen_US
dc.subjectfinite element analysisen_US
dc.titleDentofacial Effects of Fixed Functional Appliances with or without Mini Screw Anchorage in the Treatment of Class II Division I Malocclusion: A Finite Element Analysisen_US
dc.typearticleen_US
dc.relation.journalTURKISH JOURNAL OF ORTHODONTICSen_US
dc.contributor.department[Akis, Halil -- Doruk, Cenk] Cumhuriyet Univ, Dept Orthodont, Sch Dent, Sivas, Turkeyen_US
dc.identifier.volume31en_US
dc.identifier.issue1en_US
dc.identifier.endpage12en_US
dc.identifier.startpage7en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record