Show simple item record

dc.contributor.authorAltunay, Nail
dc.contributor.authorElik, Adil
dc.contributor.authorGurkan, Ramazan
dc.date.accessioned2019-07-27T12:10:23Z
dc.date.accessioned2019-07-28T09:38:58Z
dc.date.available2019-07-27T12:10:23Z
dc.date.available2019-07-28T09:38:58Z
dc.date.issued2018
dc.identifier.issn1944-0049
dc.identifier.issn1944-0057
dc.identifier.urihttps://dx.doi.org/10.1080/19440049.2017.1394585
dc.identifier.urihttps://hdl.handle.net/20.500.12418/6448
dc.descriptionWOS: 000424170300005en_US
dc.descriptionPubMed ID: 29052472en_US
dc.description.abstractAcrylamide (AAm) is a carcinogenic chemical that can form in thermally processed foods by the Maillard reaction of glucose with asparagine. AAm can easily be formed especially in frequently consumed chips and cereal-based foods depending on processing conditions. Considering these properties of AAm, a new, simple and green method is proposed for the extraction of AAm from thermally processed food samples. In this study, an ionic liquid (1-butyl-3-methylimidazolium tetrafluoroborate, [Bmim][BF4]) as extractant was used in the presence of a cationic phenazine group dye, 3,7-diamino-5-phenylphenazinium chloride (PSH+, phenosafranine) at pH 7.5 for the extraction of AAm as an ion-pair complex from selected samples. Under optimum conditions, the analytical features obtained for the proposed method were as follows; linear working range, the limits of detection (LOD, 3S(b)/m) and quantification (LOQ, 10S(b)/m), preconcentration factor, sensitivity enhancement factor, sample volume and recovery% were 2.2-350 mu g kg(-1), 0.7 mu g kg(-1), 2.3 mu g kg(-1), 120, 95, 60 mL and 94.1-102.7%, respectively. The validity of the method was tested by analysis of two certified reference materials (CRMs) and intra-day and inter-day precision studies. Finally, the method was successfully applied to the determination of AAm levels in thermally processed foods using the standard addition method.en_US
dc.description.sponsorshipCumhuriyet University Scientific Research [F-520]en_US
dc.description.sponsorshipThis work was supported by the Cumhuriyet University Scientific Research; [F-520].en_US
dc.language.isoengen_US
dc.publisherTAYLOR & FRANCIS LTDen_US
dc.relation.isversionof10.1080/19440049.2017.1394585en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAcrylamideen_US
dc.subjectthermally processed foodsen_US
dc.subjectmicroextractionen_US
dc.subjectspectrophotometryen_US
dc.titleExtraction and reliable determination of acrylamide from thermally processed foods using ionic liquid-based ultrasound-assisted selective microextraction combined with spectrophotometryen_US
dc.typearticleen_US
dc.relation.journalFOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENTen_US
dc.contributor.department[Altunay, Nail -- Elik, Adil -- Gurkan, Ramazan] Cumhuriyet Univ, Dept Chem, Fac Sci, Sivas, Turkeyen_US
dc.identifier.volume35en_US
dc.identifier.issue2en_US
dc.identifier.endpage232en_US
dc.identifier.startpage222en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record