Show simple item record

dc.contributor.authorKaplanoglu, Hatice
dc.contributor.authorBeton, Osman
dc.date.accessioned2019-07-27T12:10:23Z
dc.date.accessioned2019-07-28T09:41:22Z
dc.date.available2019-07-27T12:10:23Z
dc.date.available2019-07-28T09:41:22Z
dc.date.issued2017
dc.identifier.issn0091-2751
dc.identifier.issn1097-0096
dc.identifier.urihttps://dx.doi.org/10.1002/jcu.22440
dc.identifier.urihttps://hdl.handle.net/20.500.12418/6797
dc.descriptionWOS: 000398824600003en_US
dc.descriptionPubMed ID: 28164311en_US
dc.description.abstractPurposeTransradial and transulnar artery approaches are commonly used for percutaneous interventions, with considerably low risk of developing hand ischemia, for reasons that have not been fully understood. The aim of this study was to evaluate the changes in the diameter, peak systolic flow velocity (PSV), and volume flow (VF) of the radial (RA) and ulnar artery (UA) during unilateral reciprocal temporary occlusion. MethodsA total of 204 extremity arteries of 102 consecutive patients were evaluated using Doppler ultrasonography. At the level of the wrist, RA and UA were consecutively compressed for 60 seconds. The diameter, PSV, and VF parameters of both arteries were evaluated during unilateral reciprocal compression. ResultsCompared with the baseline values, the median (interquartile range) increases in diameter, PSV, and VF were 0.2 (0.1-0.3) mm, 6.8 (1.7-17.5) cm/s, and 1.9 (0.8-10) ml/min, respectively, for RA, and 0.1 (0.1-0.3) mm, 9.4 (2.6-18.0) cm/s, and 10.0 (0.0-20.0) ml/min, respectively, for UA during reciprocal compression (p < 0.001 for all). ConclusionsReciprocal compression significantly increased the diameter, PSV, and VF of both arteries during reciprocal compression. (c) 2016 Wiley Periodicals, Inc. J Clin Ultrasound45:197-203, 2017;en_US
dc.language.isoengen_US
dc.publisherWILEYen_US
dc.relation.isversionof10.1002/jcu.22440en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectradial arteryen_US
dc.subjectulnar arteryen_US
dc.subjectreciprocal compressionen_US
dc.subjectcardiac catheterizationen_US
dc.subjectradial artery occlusionen_US
dc.subjectDoppler ultrasonographyen_US
dc.titleFlow and Diameter Changes of Forearm Arteries During Temporary Unilateral Reciprocal Occlusion: A Prospective Observational Studyen_US
dc.typearticleen_US
dc.relation.journalJOURNAL OF CLINICAL ULTRASOUNDen_US
dc.contributor.department[Kaplanoglu, Hatice] Diskapi Yildirim Beyazit Training & Res Hosp, Dept Radiol, TR-06100 Ankara, Turkey -- [Beton, Osman] Cumhuriyet Univ, Dept Cardiol, Heart Ctr, Sivas, Turkeyen_US
dc.identifier.volume45en_US
dc.identifier.issue4en_US
dc.identifier.endpage203en_US
dc.identifier.startpage197en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record