Show simple item record

dc.contributor.authorKobya, M.
dc.contributor.authorDemirbas, E.
dc.contributor.authorOzyonar, F.
dc.contributor.authorSirtbas, G.
dc.contributor.authorGengec, E.
dc.date.accessioned2019-07-27T12:10:23Z
dc.date.accessioned2019-07-28T09:44:24Z
dc.date.available2019-07-27T12:10:23Z
dc.date.available2019-07-28T09:44:24Z
dc.date.issued2017
dc.identifier.issn0957-5820
dc.identifier.issn1744-3598
dc.identifier.urihttps://dx.doi.org/10.1016/j.psep.2016.11.020
dc.identifier.urihttps://hdl.handle.net/20.500.12418/7051
dc.descriptionWOS: 000392789200037en_US
dc.description.abstractTreatments of alkaline non-cyanide, alkaline cyanide and acidic zinc electroplating rinse wastewaters were investigated in an electrocoagulation (EC) reactor using Fe plate electrodes. This is the first study involved with removals of zinc and cyanide together from three different wastewaters in the literature. The effects of the operating parameters namely, initial pH (pH(i)), current density and operating time on the removal efficiencies were evaluated. The removal efficiencies and operating costs were determined as 99.8% for Zn and 0.74(sic)/m(3) at a pH of 7, 80 A/m(2) and 60 min for alkaline non-cyanide, 99.9% for Zn, 99.9% for CN and 1.72(sic)/m(3) at a pH of 9.5, 60 A/m(2) and 60 min for alkaline cyanide, and 99.9% for Zn and 2.26(sic)/m(3) at a pH of 8, 80 A/m(2) and 60 min for acidic zinc electroplating wastewaters, respectively. Moreover, toxicity test was conducted to obtain information about the toxic effect of the raw and treated wastewaters. The toxicity results indicated that all the raw wastewaters contained hardly toxic effect (ECso for acidic, alkaline cyanide and alkaline non-cyanide were 0.62, 5.25 and 3.38). On the other hand, the treated wastewater was non-toxic. This study revealed that the EC process with Fe electrode was very effective for removal of zinc and cyanide ions from different zinc electroplating rinse wastewaters. (C) 2016 Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.en_US
dc.description.sponsorshipGebze Technical University [BAP-2013-A18]en_US
dc.description.sponsorshipThe authors thank to Gebze Technical University for their financial support of this project under contract of BAP-2013-A18.en_US
dc.language.isoengen_US
dc.publisherINST CHEMICAL ENGINEERSen_US
dc.relation.isversionof10.1016/j.psep.2016.11.020en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectZinc plating wastewateren_US
dc.subjectAlkaline non-cyanideen_US
dc.subjectAlkaline cyanideen_US
dc.subjectAcidic zincen_US
dc.subjectElectrocoagulationen_US
dc.subjectOperating costen_US
dc.subjectIron electrodeen_US
dc.titleTreatments of alkaline non-cyanide, alkaline cyanide and acidic zinc electroplating wastewaters by electrocoagulationen_US
dc.typearticleen_US
dc.relation.journalPROCESS SAFETY AND ENVIRONMENTAL PROTECTIONen_US
dc.contributor.department[Kobya, M. -- Sirtbas, G.] Gebze Tech Univ, Dept Environm Engn, TR-41400 Gebze, Turkey -- [Demirbas, E.] Gebze Tech Univ, Dept Chem, TR-41400 Gebze, Turkey -- [Ozyonar, F.] Cumhuriyet Univ, Dept Environm Engn, Sivas, Turkey -- [Gengec, E.] Kocaeli Univ, Environm Protect Dept, Kocaeli, Turkeyen_US
dc.contributor.authorIDGengec, Erhan -- 0000-0003-3666-0791; KOBYA, Mehmet -- 0000-0001-5052-7220en_US
dc.identifier.volume105en_US
dc.identifier.endpage385en_US
dc.identifier.startpage373en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record