Show simple item record

dc.contributor.authorGurkan, Ramazan
dc.contributor.authorAltunay, Nail
dc.date.accessioned2019-07-27T12:10:23Z
dc.date.accessioned2019-07-28T09:45:10Z
dc.date.available2019-07-27T12:10:23Z
dc.date.available2019-07-28T09:45:10Z
dc.date.issued2016
dc.identifier.issn1944-0049
dc.identifier.issn1944-0057
dc.identifier.urihttps://dx.doi.org/10.1080/19440049.2016.1191380
dc.identifier.urihttps://hdl.handle.net/20.500.12418/7273
dc.descriptionWOS: 000381015000004en_US
dc.descriptionPubMed ID: 27194513en_US
dc.description.abstractA simple and efficient ultrasonic-assisted extraction (UAE) procedure has been proposed for the pre-concentration of (2S)-2-[(4-{[(2-amino-4-hydroxypteridin-yl)methyl]amino}phenyl)formamido]pentanedioic acid (folic acid) in vegetables, pharmaceuticals and foods prior to determination at 540nm using UV-Vis spectrophotometry. The method is based on hydrophobic ternary complex formation of folic acid with silver ions in the presence of cetyltrimethylammonium bromide (CTAB) as a sensitivity enhancer counter ion at pH 7.0, and then extraction into a micellar phase of polyethylene glycol monoalkyl ether (Genapol X-080). The impacts on the extraction efficiency and complex formation of analytical parameters such as sample pH, concentration of silver, concentration of surfactants and extraction time, ultrasonic time and sample volume, were investigated and optimised in detail. The matrix effect on the pre-concentration and determination of folic acid was investigated, and it was observed that the proposed method was highly selective against possible matrix co-extractives. Under optimised conditions, a good linear relationship between the analytical signal and folic acid concentration was obtained in the range of 0.6-180gl(-1) with a detection limit of 0.19gl(-1) and quantification limit of 0.63gl(-1). The applicability was evaluated using samples fortified at different concentration levels, and recoveries higher than 94.1% were obtained. The precision as the percent relative standard deviation (RSD%) was in range of 2.5-3.8% (10 and 40gl(-1), n = 5). The proposed method was validated by analysis of two standard reference materials (SRMs) and various real samples, and satisfactory results were obtained.en_US
dc.language.isoengen_US
dc.publisherTAYLOR & FRANCIS LTDen_US
dc.relation.isversionof10.1080/19440049.2016.1191380en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectFolic aciden_US
dc.subjectvegetablesen_US
dc.subjectsilveren_US
dc.subjectultrasonic-assisted extractionen_US
dc.subjectspectrophotometryen_US
dc.titleA simple and efficient ultrasonic-assisted extraction procedure combined with UV-Vis spectrophotometry for the pre-concentration and determination of folic acid (vitamin B-9) in various sample matricesen_US
dc.typearticleen_US
dc.relation.journalFOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENTen_US
dc.contributor.department[Gurkan, Ramazan -- Altunay, Nail] Cumhuriyet Univ, Dept Chem, Fac Sci, TR-58140 Sivas, Turkeyen_US
dc.identifier.volume33en_US
dc.identifier.issue7en_US
dc.identifier.endpage1138en_US
dc.identifier.startpage1127en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record