Show simple item record

dc.contributor.authorAltunay, Nail
dc.contributor.authorGurkan, Ramazan
dc.date.accessioned2019-07-27T12:10:23Z
dc.date.accessioned2019-07-28T09:46:23Z
dc.date.available2019-07-27T12:10:23Z
dc.date.available2019-07-28T09:46:23Z
dc.date.issued2016
dc.identifier.issn1300-0527
dc.identifier.urihttps://dx.doi.org/10.3906/kim-1604-76
dc.identifier.urihttps://hdl.handle.net/20.500.12418/7512
dc.descriptionWOS: 000390326500013en_US
dc.description.abstractIn the current study, a simple and efficient analytical method for preconcentration and determination of Cd(II), Pb(II), and Sn(II) in some cosmetic samples, using ultrasonic assisted-cloud point extraction and flame atomic absorption spectrometry, was developed. The method is based on the ternary complex formations of Sn(II), Pb(II), and Cd(II), which are available in the form of neutral and/or anionic hydroxo complexes (Sn(OH)(3)(-) Pb(OH)(3)(-) Cd(OH)(2), and/or Cd(OH)(3)(-)), with Victoria Pure Blue BO (VPB+) in the presence of cetylpyridinium chloride at pH 8.5, and then extraction of the formed ternary complexes into the micellar phase of polyoxyethylene sorbitan monostearate (Tween 60). Using the optimized conditions, a linear relationship was observed in the ranges of 12-330 mu g L-1 for Cd(II), 4-200 mu g L-1 for Pb(II), and 1-275 mu g L-1 for Sn(II). The detection limits for Cd(II), Pb(II), and Sn(II), respectively, were 3.70, 1.35, and 0.45 mu g L-1, with a preconcentration factor of 50, and the precision as relative standard deviations was lower than 4.2% for each analyte. The validity was verified by analysis of two certified reference materials. Finally, the method was successfully applied to the determination of these metals in various cosmetic samples.en_US
dc.description.sponsorshipCumhuriyet University Scientific Research Projects Commission (CUBAP), Sivas, Turkey [F-445]en_US
dc.description.sponsorshipFinancial support from the Cumhuriyet University Scientific Research Projects Commission (CUBAP with projects number of F-445), Sivas, Turkey, is sincerely appreciated.en_US
dc.language.isoengen_US
dc.publisherSCIENTIFIC TECHNICAL RESEARCH COUNCIL TURKEY-TUBITAKen_US
dc.relation.isversionof10.3906/kim-1604-76en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectExtractionen_US
dc.subjectgreen chemistryen_US
dc.subjectheavy metalsen_US
dc.subjectpollutionen_US
dc.subjectspectroscopyen_US
dc.subjectsurfactantsen_US
dc.titleA simple and efficient approach for preconcentration of some heavy metals in cosmetic products before their determinations by flame atomic absorption spectrometryen_US
dc.typearticleen_US
dc.relation.journalTURKISH JOURNAL OF CHEMISTRYen_US
dc.contributor.department[Altunay, Nail -- Gurkan, Ramazan] Cumhuriyet Univ, Dept Chem, Fac Sci, Sivas, Turkeyen_US
dc.identifier.volume40en_US
dc.identifier.issue6en_US
dc.identifier.endpage1001en_US
dc.identifier.startpage988en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record