Show simple item record

dc.contributor.authorOznurhan, Fatih
dc.contributor.authorUnal, Murat
dc.contributor.authorKapdan, Arife
dc.contributor.authorOzturk, Ceren
dc.contributor.authorAksoy, Serkan
dc.date.accessioned2019-07-27T12:10:23Z
dc.date.accessioned2019-07-28T09:56:11Z
dc.date.available2019-07-27T12:10:23Z
dc.date.available2019-07-28T09:56:11Z
dc.date.issued2015
dc.identifier.issn0960-7439
dc.identifier.issn1365-263X
dc.identifier.urihttps://dx.doi.org/10.1111/ipd.12128
dc.identifier.urihttps://hdl.handle.net/20.500.12418/7878
dc.descriptionWOS: 000352583600006en_US
dc.descriptionPubMed ID: 25073636en_US
dc.description.abstractAimThe aim of this in vivo study was to evaluate the accuracy and reliability of electronic apex locater and radiographic determination of root canal length in primary teeth. MethodologyA total of 32 human primary molar teeth (96 roots) were selected. After endodontic access preparation, root canals were irrigated with physiological saline solution. The access cavities were dried with cotton pellets and, the roots were dried with paper points before performing the electronic measurement. The root canal length measurements were first taken with an apex locater (EndoMaster), and then, a size 15K-file was inserted into the root canal, and radiography was taken to determine the working length measurements. The measurement data were recorded and compared by one-way anova and Kruskal-Wallis tests. P<0.05 was accepted for the significance. ResultsThe mean values for radiography were 13.231.92mm and for EndoMaster were 13.08 +/- 1.77mm. The accuracy of EndoMaster was 80.2% in correct measurements +/- 1mm (P<0.001). ConclusionThe electronic apex locators could be useful in determining working length and thereby decreasing the need for radiographs and exposure to ionizing radiation in pediatric dental patients.en_US
dc.language.isoengen_US
dc.publisherWILEY-BLACKWELLen_US
dc.relation.isversionof10.1111/ipd.12128en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.titleClinical evaluation of apex locator and radiography in primary teethen_US
dc.typearticleen_US
dc.relation.journalINTERNATIONAL JOURNAL OF PAEDIATRIC DENTISTRYen_US
dc.contributor.department[Oznurhan, Fatih -- Unal, Murat -- Kapdan, Arife -- Ozturk, Ceren -- Aksoy, Serkan] Cumhuriyet Univ, Dept Pediat Dent, Fac Dent, Sivas, Turkeyen_US
dc.contributor.authorIDKaptan, Arife -- 0000-0003-4371-7768; OZNURHAN, Fatih -- 0000-0002-7797-0932en_US
dc.identifier.volume25en_US
dc.identifier.issue3en_US
dc.identifier.endpage203en_US
dc.identifier.startpage199en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US