Show simple item record

dc.contributor.authorOskay, Kursad Oguz
dc.contributor.authorKul, Mehmet
dc.date.accessioned2019-07-27T12:10:23Z
dc.date.accessioned2019-07-28T09:56:31Z
dc.date.available2019-07-27T12:10:23Z
dc.date.available2019-07-28T09:56:31Z
dc.date.issued2015
dc.identifier.issn0273-1223
dc.identifier.issn1996-9732
dc.identifier.urihttps://dx.doi.org/10.2166/wst.2015.187
dc.identifier.urihttps://hdl.handle.net/20.500.12418/8037
dc.descriptionWOS: 000357137400007en_US
dc.descriptionPubMed ID: 26114271en_US
dc.description.abstractThis study aimed to recover and remove copper from industrial model wastewater solution by non-dispersive solvent extraction (NDSX). Two mathematical models were developed to simulate the performance of an integrated extraction-stripping process, based on the use of hollow fiber contactors using the response surface method. The models allow one to predict the time dependent efficiencies of the two phases involved in individual extraction or stripping processes. The optimal recovery efficiency parameters were determined as 227 g/L of H2SO4 concentration, 1.22 feed/strip ratio, 450 mL/min flow rate (115.9 cm/min. flow velocity) and 15 volume % LIX 84-I concentration in 270 min by central composite design (CCD). At these optimum conditions, the experimental value of recovery efficiency was 95.88%, which was in close agreement with the 97.75% efficiency value predicted by the model. At the end of the process, almost all the copper in the model waste water solution was removed and recovered as CuSO4 center dot 5H(2)O salt, which can be reused in the copper electroplating industry.en_US
dc.description.sponsorshipCumhuriyet University [M-493]en_US
dc.description.sponsorshipThis work was supported by the Scientific Research Project Fund of Cumhuriyet University, under project number M-493.en_US
dc.language.isoengen_US
dc.publisherIWA PUBLISHINGen_US
dc.relation.isversionof10.2166/wst.2015.187en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCCDen_US
dc.subjectcopperen_US
dc.subjecthollow fiber membraneen_US
dc.subjectNDSXen_US
dc.subjectoptimizationen_US
dc.subjectrecoveryen_US
dc.titleOptimizing the recovery of copper from electroplating rinse bath solution by hollow fiber membraneen_US
dc.typearticleen_US
dc.relation.journalWATER SCIENCE AND TECHNOLOGYen_US
dc.contributor.department[Oskay, Kursad Oguz -- Kul, Mehmet] Cumhuriyet Univ, Met & Mat Engn, Sivas, Turkeyen_US
dc.identifier.volume72en_US
dc.identifier.issue1en_US
dc.identifier.endpage62en_US
dc.identifier.startpage52en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US