Show simple item record

dc.contributor.authorSancak, Irem Gul
dc.contributor.authorOzdemir, Ozge
dc.contributor.authorUlusan, Sinan
dc.contributor.authorBilgili, Hasan
dc.date.accessioned2019-07-27T12:10:23Z
dc.date.accessioned2019-07-28T09:57:53Z
dc.date.available2019-07-27T12:10:23Z
dc.date.available2019-07-28T09:57:53Z
dc.date.issued2014
dc.identifier.issn1300-0861
dc.identifier.urihttps://dx.doi.org/10.1501/Vetfak_0000002625
dc.identifier.urihttps://hdl.handle.net/20.500.12418/8397
dc.descriptionWOS: 000338486000003en_US
dc.description.abstractThis study covers the technique of a custom designed circular external fixator (CEF) in tibial fractures in 7 cats. All tibial fractures were surgically treated. The cases were followed-up using radiographs obtained on 25 and 48 days after surgery. Signalment, fracture localization, complications and implant diameter for each cat were noted. Ring diameters were as follows: in 4 tibial fracture cases 45 mm and in 3 tibial fracture cases 55 mm. Complications were observed in 2 cats, both of which had pin tract infection. Fracture cases were evaluated as follows: 5 of the tibial fractures had excellent results and 2 cases had good results. The CEF system was well tolerated by all the cats during the postoperative follow-up period. First use of the treated limb occurred on postoperative 1-3 day in all cases. Pin deformation or CEF breakage and distortion were not observed in any of the cases. The CEF system designed by the authors was suitable for fixation of tibial fractures in cats. Clinical use of CEF system in tibial fractures of cats is found to be useful and its use is highly recommended to our colleagues.en_US
dc.language.isoengen_US
dc.publisherANKARA UNIV PRESSen_US
dc.relation.isversionof10.1501/Vetfak_0000002625en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectCaten_US
dc.subjectcircular external skeletal fixatoren_US
dc.subjectfractureen_US
dc.subjecttibial fractureen_US
dc.subjecttibiaen_US
dc.titleTreatment of tibial fractures in seven cats using circular external skeletal fixationen_US
dc.typearticleen_US
dc.relation.journalANKARA UNIVERSITESI VETERINER FAKULTESI DERGISIen_US
dc.contributor.department[Sancak, Irem Gul -- Ulusan, Sinan -- Bilgili, Hasan] Ankara Univ, Fac Vet Med, Dept Surg, TR-06110 Ankara, Turkey -- [Ozdemir, Ozge] Cumhuriyet Univ, Fac Vet Med, Dept Surg, Sivas, Turkeyen_US
dc.identifier.volume61en_US
dc.identifier.issue3en_US
dc.identifier.endpage178en_US
dc.identifier.startpage173en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record