Show simple item record

dc.contributor.authorAkin, Hakan
dc.contributor.authorTugut, Faik
dc.contributor.authorGuney, Umit
dc.contributor.authorKirmali, Omer
dc.contributor.authorAkar, Turker
dc.date.accessioned2019-07-27T12:10:23Z
dc.date.accessioned2019-07-28T10:03:11Z
dc.date.available2019-07-27T12:10:23Z
dc.date.available2019-07-28T10:03:11Z
dc.date.issued2013
dc.identifier.issn0268-8921
dc.identifier.urihttps://dx.doi.org/10.1007/s10103-012-1082-7
dc.identifier.urihttps://hdl.handle.net/20.500.12418/8907
dc.descriptionWOS: 000313096400017en_US
dc.descriptionPubMed ID: 22447403en_US
dc.description.abstractThis study evaluated the effect of various surface treatments on the tensile bond strength of a silicone-based soft denture liner to two chemically different denture base resins, heat-cured polymethyl methacrylate (PMMA), and light-activated urethane dimethacrylate or Eclipse denture base resin. PMMA test specimens were fabricated and relined with a silicone-based soft denture liner (group AC). Eclipse test specimens were prepared according to the manufacturer's recommendation. Before they were relined with a silicone-based soft denture liner, each received one of three surface treatments: untreated (control, group EC), Eclipse bonding agent applied (group EB), and laser-irradiated (group EL). Tensile bond strength tests (crosshead speed = 5 mm/min) were performed for all specimens, and the results were analyzed using the analysis of variance followed by Tukey's test (p = 0.05). Eclipse denture base and PMMA resins presented similar bond strengths to the silicone-based soft denture liner. The highest mean force was observed in group EL specimens, and the tensile bond strengths in group EL were significantly different (p < 0.05) from those in the other groups.en_US
dc.language.isoengen_US
dc.publisherSPRINGER LONDON LTDen_US
dc.relation.isversionof10.1007/s10103-012-1082-7en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectPMMAen_US
dc.subjectUDMAen_US
dc.subjectEclipseen_US
dc.subjectSoft lineren_US
dc.subjectEr:YAG laseren_US
dc.subjectTensile bond strengthen_US
dc.titleTensile bond strength of silicone-based soft denture liner to two chemically different denture base resins after various surface treatmentsen_US
dc.typearticleen_US
dc.relation.journalLASERS IN MEDICAL SCIENCEen_US
dc.contributor.department[Akin, Hakan -- Tugut, Faik -- Guney, Umit -- Kirmali, Omer -- Akar, Turker] Cumhuriyet Univ, Fac Dent, Dept Prosthodont, TR-58140 Sivas, Turkeyen_US
dc.contributor.authorIDKirmali, Omer -- 0000-0002-4313-344X; Akin, Hakan -- 0000-0002-4770-4297en_US
dc.identifier.volume28en_US
dc.identifier.issue1en_US
dc.identifier.endpage123en_US
dc.identifier.startpage119en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record