Show simple item record

dc.contributor.authorKucukdurmaz, Zekeriya
dc.contributor.authorKarapinar, Hekim
dc.contributor.authorKaravelioglu, Yusuf
dc.contributor.authorAcar, Goksel
dc.contributor.authorGul, Ibrahim
dc.contributor.authorEmiroglu, Mehmet Yunus
dc.contributor.authorBulut, Mustafa
dc.contributor.authorEsen, Ali Metin
dc.date.accessioned2019-07-27T12:10:23Z
dc.date.accessioned2019-07-28T10:03:55Z
dc.date.available2019-07-27T12:10:23Z
dc.date.available2019-07-28T10:03:55Z
dc.date.issued2012
dc.identifier.issn0742-2822
dc.identifier.urihttps://dx.doi.org/10.1111/j.1540-8175.2011.01614.x
dc.identifier.urihttps://hdl.handle.net/20.500.12418/9189
dc.descriptionWOS: 000302540700020en_US
dc.descriptionPubMed ID: 22324433en_US
dc.description.abstractPurpose: We aimed to investigate the effect of controlled and limited volume change by the blood donation model to the right ventricular (RV) function via different echocardiographic parameters in healthy adults. Methods: Study population was composed of 71 healthy subjects who were volunteers for blood donation and evaluated before and after 450 mL blood donation. Pulsed-wave Doppler of the RV inflow and tissue Doppler of tricuspid lateral annulus, and tricuspid annular plane systolic excursion (TAPSE) were assessed. Results: E velocity of inflow decreased significantly (67.6 +/- 15.9 vs 60.9 +/- 12.2, P = 0.006). S and A velocities did not change (15.3 +/- 3.2 vs 15.2 +/- 2.5 cm/s, P = NS; 14.1 +/- 3.3 vs 13.4 +/- 3.1 cm/s, P = NS, respectively) but E showed significant decrease (13.7 +/- 2.9 vs 12.2 +/- 3.2 cm/s, P = 0.011). E/A ratio and E/E ratio were found to be unchanged (1.0 +/- 0.3 vs 1.0 +/- 0.4, P = NS; 5.1 +/- 2 vs 5.3 +/- 2, P = NS, respectively). Myocardial performance index (MPI) was found to be increased but ejection time obtained from the tricuspid annulus did not change (0.50 +/- 0.13 vs 0.54 +/- 0.11, P = 0.040; 243 +/- 37 vs 240 +/- 27, P = NS, respectively). Isovolumetric relaxation and contraction times showed difference close to the significance limit (56 +/- 19 vs 64 +/- 23 ms, P = 0.055; 61 +/- 16 vs 67 +/- 16 ms, P = 0.062, respectively). TAPSE decreased significantly (2.62 +/- 0.29 vs 2.41 +/- 0.27 mm, P = 0.005). Conclusion: E velocity and TAPSE were sensitive to a volume reduction as little as 450 mL in healthy subjects. MPI index of the tricuspid annulus is less sensitive than E and TAPSE but need much care under changing volume state. However S and A velocity and E/A ratio were found to be resistant to the effects of volume depletion. (Echocardiography 2012;29:451-454)en_US
dc.language.isoengen_US
dc.publisherWILEY-BLACKWELLen_US
dc.relation.isversionof10.1111/j.1540-8175.2011.01614.xen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectright hearten_US
dc.subjectsystolic functionen_US
dc.subjecttissue Doppleren_US
dc.subjectmyocardial performance indexen_US
dc.subjecttricuspid annular plane systolic excursionen_US
dc.titleEffect of Blood Donation Mediated Volume Reduction on Right Ventricular Function Parameters in Healthy Subjectsen_US
dc.typearticleen_US
dc.relation.journalECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUESen_US
dc.contributor.department[Kucukdurmaz, Zekeriya -- Karapinar, Hekim -- Gul, Ibrahim] Cumhuriyet Univ, Dept Cardiol, Sch Med, Sivas, Turkey -- [Karapinar, Hekim -- Karavelioglu, Yusuf -- Acar, Goksel -- Emiroglu, Mehmet Yunus -- Bulut, Mustafa -- Esen, Ali Metin] Kartal Kosuyolu High Specialty Educ & Res Hosp, Dept Cardiol, Istanbul, Turkeyen_US
dc.identifier.volume29en_US
dc.identifier.issue4en_US
dc.identifier.endpage454en_US
dc.identifier.startpage451en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record