dc.contributor.author | Akin, Hakan | |
dc.contributor.author | Coskun, M. Emre | |
dc.contributor.author | Akin, E. Gulsah | |
dc.contributor.author | Ozdemir, A. Kemal | |
dc.date.accessioned | 2019-07-27T12:10:23Z | |
dc.date.accessioned | 2019-07-28T10:05:53Z | |
dc.date.available | 2019-07-27T12:10:23Z | |
dc.date.available | 2019-07-28T10:05:53Z | |
dc.date.issued | 2011 | |
dc.identifier.issn | 0022-3913 | |
dc.identifier.issn | 1097-6841 | |
dc.identifier.uri | https://dx.doi.org/10.1016/S0022-3913(11)60031-0 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12418/9588 | |
dc.description | WOS: 000289389300010 | en_US |
dc.description | PubMed ID: 21356413 | en_US |
dc.description.abstract | Statement of problem. Rare earth magnets have been used in prosthodontics, but their tendency for corrosion in the oral cavity and insufficient attractive forces limit long-term clinical application. Purpose. The purpose of this study was to evaluate the attractive force of different types of new-generation magnetic attachment systems. Material and methods. The attractive force of the neodymium-iron-boron (Nd-Fe-B) and samarium-cobalt (Sm-Co) magnetic attachment systems, including closed-field (Hilop and Hicorex) and open-field (Dyna and Steco) systems, was measured in a universal testing machine (n=5). The data were statistically evaluated with 1-way ANOVA and post hoc Tukey-Kramer multiple comparison test (alpha=.05). Results. The closed-field systems exhibited greater (P <.001) attractive force than the open-field systems. Moreover, there was a statistically significant difference in attractive force between Nd-Fe-B and Sm-Co magnets (P<.001). The strongest attractive force was found with the Hilop system (9.2 N), and the lowest force was found with the Steco system (2.3 N). Conclusions. The new generation of Nd-Fe-B closed-field magnets, along with improved technology, provides sufficient denture retention for clinical application. (J Prosthet Dent 2011;105:203-207) | en_US |
dc.description.sponsorship | Cumhuriyet University | en_US |
dc.description.sponsorship | This investigation was supported in part by Cumhuriyet University Scientific Research Project (CUBAP). | en_US |
dc.language.iso | eng | en_US |
dc.publisher | MOSBY-ELSEVIER | en_US |
dc.relation.isversionof | 10.1016/S0022-3913(11)60031-0 | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.title | EVALUATION OF THE ATTRACTIVE FORCE OF DIFFERENT TYPES OF NEW-GENERATION MAGNETIC ATTACHMENT SYSTEMS | en_US |
dc.type | article | en_US |
dc.relation.journal | JOURNAL OF PROSTHETIC DENTISTRY | en_US |
dc.contributor.department | [Akin, Hakan -- Coskun, M. Emre -- Ozdemir, A. Kemal] Cumhuriyet Univ, Fac Dent, Dept Prosthodont, TR-58140 Sivas, Turkey -- [Akin, E. Gulsah] Cumhuriyet Univ, Fac Dent, Dept Conservat Dent, TR-58140 Sivas, Turkey | en_US |
dc.contributor.authorID | Akin, Hakan -- 0000-0002-4770-4297 | en_US |
dc.identifier.volume | 105 | en_US |
dc.identifier.issue | 3 | en_US |
dc.identifier.endpage | 207 | en_US |
dc.identifier.startpage | 203 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |