EXERGY ANALYSIS OF A GROUND SOURCE HEAT PUMP SYSTEM FOR COLD CLIMATIC CONDITION OF SIVAS, TURKEY
dc.authorid | KILINC, FERHAT/0000-0003-2707-6438 | |
dc.contributor.author | Duman, Netice | |
dc.contributor.author | Buyruk, Ertan | |
dc.contributor.author | Acar, Halil Ibrahim | |
dc.contributor.author | Caner, Mustafa | |
dc.contributor.author | Kilinc, Ferhat | |
dc.contributor.author | Can, Ahmet | |
dc.date.accessioned | 2024-10-26T17:59:52Z | |
dc.date.available | 2024-10-26T17:59:52Z | |
dc.date.issued | 2021 | |
dc.department | Sivas Cumhuriyet Üniversitesi | |
dc.description | 25th Interklima International Conference -- APR 11-12, 2019 -- Zagreb, CROATIA | |
dc.description.abstract | In the present study, exergy analysis of a ground source heat pump (GSHP) is performed. For this purpose, a horizontal type GSHP test system is installed at Sivas Cumhuriyet University in Sivas Province. GSHP system consists of three main circuits. These are the ground heat exchanger (GHE), the heat pump (HP) and the heating circuit. The temperatures and pressures are measured at the various points of the system. Besides, the mass flow rate of the working fluid circulating in the GHE, heat pump and heat circuit are measured. In addition, power consumption of the compressor and the pumps are measured. Measured data were recorded every minute. The test data used in the calculations are related to the coldest day, December 18, 2016. Exergy loss, exergy efficiency, exergy loss ratio and thermodynamic perfect degree for each element of the system are computed. Exergy efficiency and thermodynamic perfect degree of the system are calculated as 0.27 and 0.86 respectively. | |
dc.description.sponsorship | Univ Zagreb, Fac Mech Engn & Naval Architecture,SDEWES Ctr,Univ Maribor, Fac Energy Technol | |
dc.description.sponsorship | Sivas Cumhuriyet University Scientific Research Projects (CUBAP) commission [M-617] | |
dc.description.sponsorship | This study is supported by Sivas Cumhuriyet University Scientific Research Projects (CUBAP) commission within the scope of M-617 project. | |
dc.identifier.doi | 10.21278/TOF.45Si1006321 | |
dc.identifier.endpage | 22 | |
dc.identifier.issn | 1333-1124 | |
dc.identifier.startpage | 13 | |
dc.identifier.uri | https://doi.org/10.21278/TOF.45Si1006321 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12418/27383 | |
dc.identifier.volume | 45 | |
dc.identifier.wos | WOS:000642341400003 | |
dc.identifier.wosquality | Q4 | |
dc.indekslendigikaynak | Web of Science | |
dc.language.iso | en | |
dc.publisher | Univ Zagreb Fac Mechanical Engineering & Naval Architecture | |
dc.relation.ispartof | Transactions of Famena | |
dc.relation.publicationcategory | Konferans Öğesi - Uluslararası - Kurum Öğretim Elemanı | |
dc.rights | info:eu-repo/semantics/closedAccess | |
dc.subject | Ground source heat pump | |
dc.subject | exergy | |
dc.subject | exergy efficiency | |
dc.subject | exergy loss | |
dc.subject | exergy loss ratio | |
dc.subject | thermodynamic perfect degree | |
dc.title | EXERGY ANALYSIS OF A GROUND SOURCE HEAT PUMP SYSTEM FOR COLD CLIMATIC CONDITION OF SIVAS, TURKEY | |
dc.type | Conference Object |