Effect of different impression materials on the marginal fit of frameworks: An in-vitro study
dc.contributor.author | Türk, Ayşe Gözde | |
dc.contributor.author | Ulusoy, Mubin | |
dc.contributor.author | YÜce, Mert | |
dc.contributor.author | Akin, Hakan | |
dc.date.accessioned | 2024-10-26T17:53:09Z | |
dc.date.available | 2024-10-26T17:53:09Z | |
dc.date.issued | 2016 | |
dc.department | Sivas Cumhuriyet Üniversitesi | |
dc.description.abstract | Objectives: The objective of this study was to compare the accuracy of three different impression materials with evaluating the marginal fits of metal frameworks using replica technique. Materials and Methods: A phantom premolar tooth was prepared with a 1 mm circumferential chamfer preparation. Four impression materials: two vinyl polysiloxane (VPS) (Affinis Precious, (Group A); Elite HD, (Group E)), one polyether (Impregum Penta Soft, (Group P)) and one vinyl siloxanether (Identium, (Group I)) were used for producing stone casts of this master model. Twelve measurements per replica were carried out using a light microscope X40 magnification by Leica software, to assess the vertical marginal gap (VMG). Data were analyzed using the analysis of variance followed by Tukey's test (p=0.05). Results: Specimens of the Group A and Group I showed significantly lower VMG values than those of Group E and Group P (p<0.001). Differences were not significant between Group A and Group I, and Group E and Group P either (p>0.05). Conclusions: All impression materials were clinically acceptable. As well as composition of the impression materials, size of filler particles and fluid mechanics of flow into very small spaces can be effective on accuracy of the materials. © 2016. All Rights Reserved. | |
dc.description.sponsorship | Ege University Scientific Research Project Fund, (09-DIS-030) | |
dc.identifier.doi | 10.7126/CUMUDJ.279867 | |
dc.identifier.endpage | 153 | |
dc.identifier.issn | 2146-2852 | |
dc.identifier.issue | 2 | |
dc.identifier.scopus | 2-s2.0-85121536403 | |
dc.identifier.scopusquality | Q4 | |
dc.identifier.startpage | 145 | |
dc.identifier.uri | https://doi.org/10.7126/CUMUDJ.279867 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12418/26758 | |
dc.identifier.volume | 19 | |
dc.indekslendigikaynak | Scopus | |
dc.language.iso | en | |
dc.publisher | Cumhuriyet University Faculty of Dentistry | |
dc.relation.ispartof | Cumhuriyet Dental Journal | |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.subject | Impression materials; marginal fit; replica technique | |
dc.title | Effect of different impression materials on the marginal fit of frameworks: An in-vitro study | |
dc.type | Article |