Comparison of Intraocular Pressure and PachymeterMeasurements Obtained by Non Contact Tonometerpachymeterwith Goldmann Applanation Tonometer andCorneal Topography
dc.contributor.author | Yeter, Duygu Yalınbas | |
dc.contributor.author | Koylu, Mehmet Talay | |
dc.contributor.author | Oguz, Yeşim Gedık | |
dc.contributor.author | Yesıltas, Yagmur Seda | |
dc.contributor.author | Akıncıoglu, Dorukcan | |
dc.contributor.author | Gurdal, Fatih | |
dc.contributor.author | Mutlu, Fatih Mehmet | |
dc.date.accessioned | 2024-10-26T17:42:37Z | |
dc.date.available | 2024-10-26T17:42:37Z | |
dc.date.issued | 2021 | |
dc.department | Sivas Cumhuriyet Üniversitesi | |
dc.description.abstract | Purpose: To compare the measurements of intraocular pressure (IOP) and central corneal thickness (CCT) by tono-pachymeter (CT-1P) with\rIOP measurements by Goldmann applanation tonometer (GAT), and CCT measurements by Pentacam.\rMaterials and Methods: Two hundred eighteen eyes of 109 patients were included in the study. Intraocular pressure measurements were\robtained by the CT-1P and GAT, whereas CCT measurements were obtained by CT-1P and Pentacam. Blant-Altman plots for agreement, and\rPearson correlation and interclass correlation (ICC) for reliability between the measurements were analyzed.\rResults: The mean IOPCT-1P, IOPCT-1P adj., IOPGAT were measured as 18.2±4.32 mmHg, 17.75±4.05 mmHg and 16.9±4.16 mmHg, respectively.\rThe mean CCT was measured as 554.8±37.3 ?m and 543.6±35.9 ?m with CT-1P and Pentacam, respectively. Mean differences between\rdevices were signifi cantly different in terms of IOP and CCT measurement (p<0.001, for all). Interclass correlation coeffi cient confi rmed the\rexcellent reliability between devices in terms of measurement of IOP and CCT (p<0.001, for all). The 95% limits of agreement (LoA) for IOP\rwere -4.24 to 3.28 mmHg between IOPCT-1P adj. and IOPCT-1P, -3.49 to 5.14 mmHg between IOPCT-1P adj. and IOPGAT and -2.7 to 5.3 mmHg between\rIOPCT-1P and IOPGAT. Also 95% LoA for CCT were -12.33 to 32.16 ?m between CCTCT-1P and CCTPentacam.\rConclusion: Although CT-1P overestimated both IOP and CCT measurements, the device had an excellent ICC with Pentacam and GAT in\rterms of CCT and IOP measurements. The ability of tono-pachymeters measuring both CCT and IOP with a single device provide an important\rconvenience in busy clinics. | |
dc.identifier.doi | 10.37844/glauc.cat.2021.16.3 | |
dc.identifier.endpage | 17 | |
dc.identifier.issn | 1305-9173 | |
dc.identifier.issn | 2717-7157 | |
dc.identifier.issue | 1 | |
dc.identifier.startpage | 12 | |
dc.identifier.trdizinid | 510894 | |
dc.identifier.uri | https://doi.org/10.37844/glauc.cat.2021.16.3 | |
dc.identifier.uri | https://search.trdizin.gov.tr/tr/yayin/detay/510894 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12418/24706 | |
dc.identifier.volume | 16 | |
dc.indekslendigikaynak | TR-Dizin | |
dc.language.iso | en | |
dc.relation.ispartof | Glokom Katarakt | |
dc.relation.publicationcategory | Makale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.title | Comparison of Intraocular Pressure and PachymeterMeasurements Obtained by Non Contact Tonometerpachymeterwith Goldmann Applanation Tonometer andCorneal Topography | |
dc.type | Article |