Show simple item record

dc.contributor.authorAltunay, Nail
dc.contributor.authorElik, Adil
dc.contributor.authorKatin, Konstantin
dc.date.accessioned2022-05-10T13:32:32Z
dc.date.available2022-05-10T13:32:32Z
dc.date.issued2021tr
dc.identifier.citationSivas Cumhuriyet Üniversitesi, Fen Fakültesi, Biyokimya Bölümü, TR-58140, Sivas, Türkiye b Sivas Cumhuriyet Üniversitesi, Fen Fakültesi, Kimya Bölümü, TR-58140, Sivas, Türkiye c Elektronik, Spintronik ve Fotonik Nanomühendislik Enstitüsü, Ulusal Araştırma Nükleer Üniversitesi “MEPhI”, Kashirskoe Shosse 31, Moskova, 115409, Rusyatr
dc.identifier.urihttps://hdl.handle.net/20.500.12418/12750
dc.description.abstractWe applied novel vortex-assisted ionic liquid dispersive liquid-liquid microextraction (VA-IL-DLLME) method to preconcentration and extraction of Se(IV) ions from water, beverage and food samples. The method was optimized using central composite design combined with the response surface analysis. After extraction, inorganic selenium species (total Se, Se(IV) and Se(VI)) were determined by hydride generation atomic absorption spectrometry. 1-n-Octyl-3-methylimidazolium bis(trifluoromethane)-sulfonamide [C8mim NTf2] and tetrahydrofuran were used as the extraction and dispersive solvents, respectively. Applied vortex assisted the extractant dispersion and accelerated the mass transfer process. Obtained optimum conditions for microextraction procedure are as follows: mass of [C8mim NTf2], pH, extraction time and THF volume should be equal to 85 mg, 6.8, 15 min and 730 μL, respectively. Under these conditions, we observed linear range, limit of detection and enrichment factor equal to 5−500ng L−1, 1.5 ng L−1 and 120, respectively. We also fount linear regression coefficients in the dependence between Absorbance and Se(IV) concentration: Absorbance = 0.0652 CSe(IV) + 0.0185. We added 200 μg kg−1 of Se(IV) to selected food samples and 100 ng L−1 of Se(IV) to selected waters and beverages. Relative standard deviations and recovery values were within the ranges of 2.4–3.5 % and 92.7÷103.4 %, respectively. The optimized VA-IL-DLLME method reported here provides high extraction efficiency, fast extraction and lower detection limit without a heating step than alternative microextraction methods. This method also requires environmental solvents for determination and preconcentration of trace Se species in the selected samples. In addition, the reported VA-IL-DLLME procedure is the first method which use [C8mim NTf2] as extraction solvent for the preconcentration and separation of Se(IV) ions.tr
dc.language.isoengtr
dc.publisherElseviertr
dc.relation.isversionof10.1016/j.jfca.2021.103871tr
dc.rightsinfo:eu-repo/semantics/closedAccesstr
dc.subjectSeleniumExperimental designFood analysisFood compositionRoom temperature ionic liquidHydride generation atomic absorption spectrometrytr
dc.titleOptimization of vortex-assisted ionic liquid dispersive liquid–liquid microextraction by experimental design prior to hydride generation atomic absorption spectrometry for determination of selenium species in food, beverage and water samplestr
dc.typearticletr
dc.relation.journalJournal of Food Composition and Analysistr
dc.contributor.departmentFen Fakültesitr
dc.identifier.volume99tr
dc.identifier.issue99tr
dc.identifier.endpage103871tr
dc.identifier.startpage103871tr
dc.relation.publicationcategoryUluslararası Hakemli Dergide Makale - Kurum Öğretim Elemanıtr


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record