Show simple item record

dc.contributor.authorSarıkaya,Merve
dc.contributor.authorUlusoy, Halil İbrahim
dc.contributor.authorMorgül, Ümmügülsüm
dc.contributor.authorUlusoy, Songül
dc.contributor.authorTartaglia, Angela
dc.contributor.authorUlusoy, Songül
dc.contributor.authorSoylak, Mustafa
dc.contributor.authorLocatelli, Marcello
dc.contributor.authorKabir,Abuzar
dc.date.accessioned2022-05-15T12:44:35Z
dc.date.available2022-05-15T12:44:35Z
dc.date.issued26.04.2021tr
dc.identifier.urihttps://hdl.handle.net/20.500.12418/13112
dc.description.abstractA new analyte separation and preconcentration method for the trace determination of antidepressant drugs, Fluoxetine (FLU) and Citalopram (CIT) in urine and wastewaters, was developed based on HPLC- DAD analysis after magnetic solid phase extraction (MSPE). In the proposed method, FLU and CIT were retained on the newly synthetized magnetic sorbent (Fe 3 O 4 @PPy-GO) in the presence of buffer (pH 10.0) and then were desorbed into a lower volume of acetonitrile prior to the chromatographic determinations. Before HPLC analysis, all samples were filtered through a 0.45 μm PTFE filter. Experimental parameters such as interaction time, desorption solvent and volume, and pH were studied and optimized in order to establish the detection limit, linearity, enrichment factor and other analytical figures of merit under optimum operation conditions. In the developed method, FLU and CIT were analyzed by diode array de- tector at the corresponding maximum wavelengths of 227 and 238 nm, respectively, by using an isocratic elution of 60% pH 3.0 buffer, 30% acetonitrile, and 10% methanol. By using the optimum conditions, limit of detections for FLU and CIT were 1.58 and 1.43 ng mL −1 , respectively, while the limit of quantifica- tions was 4.82 and 4.71 ng mL −1 , respectively. Relative standard deviations (RSD%) for triplicate analyses of model solutions containing 100 ng mL −1 target molecules were found to be less than 5.0 %. Finally, the method was successfully applied to urine (both simulated and real healthy human) and wastewater samples, and quantitative results were obtained in recovery experiments.tr
dc.language.isoengtr
dc.publisherElseviertr
dc.relation.isversionofhttps://doi.org/10.1016/j.chroma.2021.462215tr
dc.rightsinfo:eu-repo/semantics/closedAccesstr
dc.subjectFluoxetine, Citalopram HPLC Magnetic solid phase extraction Urine samples, Environmental water samplestr
dc.titleSensitive determination of Fluoxetine and Citalopram antidepressants in urine and wastewater samples by liquid chromatography coupled with photodiode array detectortr
dc.typeanimationtr
dc.relation.journalJournal of Chromatography Atr
dc.contributor.departmentEczacılık Fakültesitr
dc.contributor.authorID0000-0002-8742-5145tr
dc.identifier.volume1648tr
dc.identifier.startpage462215tr
dc.relation.publicationcategoryRaportr


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record