JavaScript is disabled for your browser. Some features of this site may not work without it.

Energy and exergy analysis of a ground source heat pump system with a slinky ground heat exchanger supported by nanofluid

Thumbnail

View/Open

s10973-020-10498-0_abstract.pdf (445.7Kb)

Date

2022

Author

Kapıcıoğlu, Abdullah

Metadata

Show full item record

Citation

Kapicioglu, A. Energy and exergy analysis of a ground source heat pump system with a slinky ground heat exchanger supported by nanofluid. J Therm Anal Calorim 147, 1455–1468 (2022). https://doi.org/10.1007/s10973-020-10498-0

Abstract

This work contains the experimental analysis results in real environment conditions of the use of Al2O3 -based nanofluid (NF) at different concentration ratios (0.1% and 0.2%) in a ground source heat pump (GSHP) system with a slinky ground heat exchanger (GHE). The energetic and exergic efficiencies of the system were investigated with the data obtained from the experimental results of base fluid (ethylene glycol (EG)-water) (EG volumetric ratio 25%) and NF with Al2O3 concentration ratios of 0.1% and 0.2%. The exergetic model is obtained by applying energy and exergy equations for each system component. Exergetic efficiencies of the system components are evaluated separately and their potential for improvement is presented. According to the results of the energetic analysis, the overall system’s coefficient of performance (COP) values for the base fluid and NF with concentration ratios of 0.1% and 0.2% were 4.30, 4.38 and 4.34, respectively. These results show that NF contributes to system performance. However, an increase in system performance was not achieved due to the increase in NF concentration; on the contrary, a decrease in performance was observed. Exergetic efficiencies of the system for base fluid and NF with concentration ratios of 0.1% and 0.2% were 88.3%, 89.7% and 89.0%, respectively, for the heat pump unit, while these values were 78.7%, 79.3% and 79.0% for the entire system, respectively. The results show that the usage of NF with low concentration ratios increases the energetic and exergic efficiency of the system.

Source

Journal of Thermal Analysis and Calorimetry

Volume

147

URI

https://link.springer.com/article/10.1007/s10973-020-10498-0
https://hdl.handle.net/20.500.12418/13357

Collections

  • İmalat Mühendisliği Bölümü Makale Koleksiyonu [32]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




Open Access Policy
About Open Access
User Guide
Contact

DSpace@Cumhuriyet

by OpenAIRE
Advanced Search

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeDepartmentPublisherCategoryLanguageAccess TypeThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeDepartmentPublisherCategoryLanguageAccess Type

My Account

LoginRegister

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Sivas Cumhuriyet University || Library || Open Access Policy || About Open Access || User Guide || OAI-PMH ||

Kütüphane ve Dokümantasyon Daire Başkanlığı, Sivas, Turkey
If you find any errors in content, please contact: acikerisim-yardim@cumhuriyet.edu.tr

Creative Commons License
DSpace@Cumhuriyet by Sivas Cumhuriyet University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

Sivas Cumhuriyet University is a member of the following institutions.


DSpace 6.3

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.